IN74HC534A
DC ELECTRICAL CHARACTERISTICS (Voltages Referenced to GND)
VCC
V
Guaranteed Limit
Symbol
VIH
Parameter
Test Conditions
Unit
V
25 °C
to
≤85
°C
≤125
°C
-55°C
Minimum High-Level VOUT=0.1 V or VCC-0.1 V
Input Voltage
2.0
4.5
6.0
1.5
3.15
4.2
1.5
3.15
4.2
1.5
3.15
4.2
IOUT≤ 20 µA
VIL
Maximum Low -
Level Input Voltage
VOUT=0.1 V or VCC-0.1 V
2.0
4.5
6.0
0.5
1.35
1.8
0.5
1.35
1.8
0.5
1.35
1.8
V
IOUT ≤ 20 µA
VOH
Minimum High-Level VIN=VIH or VIL
Output Voltage
2.0
4.5
6.0
1.9
4.4
5.9
1.9
4.4
5.9
1.9
4.4
5.9
V
IOUT ≤ 20 µA
VIN=VIH or VIL
IOUT ≤ 6.0 mA
IOUT ≤ 7.8 mA
4.5
6.0
3.98
5.48
3.84
5.34
3.7
5.2
VOL
Maximum Low-Level VIN= VIL or VIH
Output Voltage
2.0
4.5
6.0
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
0.1
V
IOUT ≤ 20 µA
VIN= VIL or VIH
IOUT ≤ 6.0 mA
IOUT ≤7.8 mA
4.5
6.0
0.26
0.26
0.33
0.33
0.4
0.4
IIN
Maximum Input
Leakage Current
VIN=VCC or GND
6.0
6.0
0.1
0.5
1.0
5.0
1.0
10
µA
µA
IOZ
Maximum Three
State Leakage
Current
Output in High-Impedance
State
VIN =VIH or VIL
VOUT= VCC or GND
ICC
Maximum Quiescent
Supply Current
(per Package)
VIN=VCC or GND
6.0
4.0
40
160
µA
I
OUT=0µA