欢迎访问ic37.com |
会员登录 免费注册
发布采购

IN74HC192AD 参数 Datasheet PDF下载

IN74HC192AD图片预览
型号: IN74HC192AD
PDF下载: 下载PDF文件 查看货源
内容描述: 可预置BCD /十年增/减计数器高性能硅栅CMOS [Presettable BCD/Decade UP/DOWN Counter High-Performance Silicon-Gate CMOS]
分类和应用: 计数器
文件页数/大小: 8 页 / 244 K
品牌: IKSEMICON [ IK SEMICON CO., LTD ]
 浏览型号IN74HC192AD的Datasheet PDF文件第1页浏览型号IN74HC192AD的Datasheet PDF文件第2页浏览型号IN74HC192AD的Datasheet PDF文件第4页浏览型号IN74HC192AD的Datasheet PDF文件第5页浏览型号IN74HC192AD的Datasheet PDF文件第6页浏览型号IN74HC192AD的Datasheet PDF文件第7页浏览型号IN74HC192AD的Datasheet PDF文件第8页  
IN74HC192A  
DC ELECTRICAL CHARACTERISTICS (Voltages Referenced to GND)  
VCC  
V
Guaranteed Limit  
Symbol  
VIH  
Parameter  
Test Conditions  
Unit  
V
25 °C  
to  
85  
°C  
125  
°C  
-55°C  
Minimum High-Level VOUT=0.1 V or VCC-0.1 V  
Input Voltage  
2.0  
4.5  
6.0  
1.5  
3.15  
4.2  
1.5  
3.15  
4.2  
1.5  
3.15  
4.2  
IOUT20 µA  
VIL  
Maximum Low -  
Level Input Voltage  
VOUT=0.1 V or VCC-0.1 V  
2.0  
4.5  
6.0  
0.3  
0.9  
1.2  
0.3  
0.9  
1.2  
0.3  
0.9  
1.2  
V
IOUT20 µA  
VOH  
Minimum High-Level VIN=VIH or VIL  
Output Voltage  
2.0  
4.5  
6.0  
1.9  
4.4  
5.9  
1.9  
4.4  
5.9  
1.9  
4.4  
5.9  
V
IOUT20 µA  
VIN=VIH or VIL  
IOUT4.0 mA  
IOUT5.2 mA  
4.5  
6.0  
3.98  
5.48  
3.84  
5.34  
3.7  
5.2  
VOL  
Maximum Low-Level VIN=VIH or VIL  
Output Voltage  
2.0  
4.5  
6.0  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
0.1  
V
IOUT20 µA  
VIN=VIH or VIL  
IOUT4.0 mA  
IOUT5.2 mA  
4.5  
6.0  
0.26  
0.26  
0.33  
0.33  
0.4  
0.4  
IIN  
Maximum Input  
Leakage Current  
VIN=VCC or GND  
6.0  
0.1  
1.0  
1.0  
µA  
µA  
ICC  
Maximum Quiescent  
Supply Current  
(per Package)  
VIN=VCC or GND  
6.0  
8.0  
80  
160  
I
OUT=0µA  
FUNCTION TABLE  
Inputs  
Mode  
The IN74HC192 can be preset to any state, but  
will not count beyond 9. If preset to state 10, 11, 12,  
13, 14 or 15, it will follow the sequence 10, 11, 6: 12,  
13, 4: 14, 15, 2 if counting Up, and follow the  
sequence 15, 14, 13, 12, 11, 10, 9 if counting Down.  
Logic equations  
MR PL  
CPU  
X
CPD  
X
H
L
L
L
L
L
X
L
Reset(Asyn.)  
Preset(Asyn.)  
No Count  
X
X
H
H
H
H
H
For Terminal Count:  
H
Count Up  
TCU = Q0 Q3 CPU  
H
H
Count Down  
No Count  
TCD = Q0 Q1 Q2 Q3 CPD  
X = don’t care  
Rev. 00