IN74ACT245
DC ELECTRICAL CHARACTERISTICS (Voltages Referenced to GND)
VCC
V
Guaranteed Limits
Symbol
VIH
Parameter
Test Conditions
VOUT=0.1 V or VCC-0.1 V
VOUT=0.1 V or VCC-0.1 V
IOUT ≤ -50 µA
Unit
V
25 °C
-40°C to
85°C
Minimum High-
Level Input Voltage
4.5
5.5
2.0
2.0
2.0
2.0
VIL
Maximum Low -
Level Input Voltage
4.5
5.5
0.8
0.8
0.8
0.8
V
VOH
Minimum High-
Level Output Voltage
4.5
5.5
4.4
5.4
4.4
5.4
V
*VIN=VIH or VIL
IOH=-24 mA
IOH=-24 mA
4.5
5.5
3.86
4.86
3.76
4.76
VOL
Maximum Low-
Level Output Voltage
4.5
5.5
0.1
0.1
0.1
0.1
V
IOUT ≤ 50 µA
*VIN=VIH or VIL
IOL=24 mA
IOL=24 mA
4.5
5.5
0.36
0.36
0.44
0.44
IIN
∆ICCT
IOZ
Maximum Input
Leakage Current
VIN=VCC or GND
VIN=VCC - 2.1 V
5.5
5.5
5.5
±0.1
±1.0
µA
mA
µA
Additional Max.
ICC/Input
1.5
Maximum Three-
State Leakage
Current
VIN (OE)= VIH or VIL
VIN =VCC or GND
VOUT =VCC or GND
±0.6
±6.0
IOLD
IOHD
ICC
+Minimum Dynamic VOLD=1.65 V Max
Output Current
5.5
5.5
5.5
75
-75
80
mA
mA
µA
+Minimum Dynamic VOHD=3.85 V Min
Output Current
Maximum Quiescent
Supply Current
(per Package)
VIN=VCC or GND
8.0
* All outputs loaded; thresholds on input associated with output under test.
+Maximum test duration 2.0 ms, one output loaded at a time.
Rev. 00