IN74AC132
DC ELECTRICAL CHARACTERISTICS (Voltages Referenced to GND)
VCC Guaranteed Limits
Symbol
VOH
Parameter
Test Conditions
V
Unit
V
25 °C
-40°C to
85°C
Minimum High-Level
Output Voltage
3.0
4.5
5.5
2.9
4.4
5.4
2.9
4.4
5.4
I
OUT ≤ -50 µA
*VIN ≤ VT - min or VT +max
IOH=-12 mA
IOH=-24 mA
3.0
4.5
5.5
2.56
3.86
4.86
2.46
3.76
4.76
IOH=-24 mA
VOL
Maximum Low-Level
Output Voltage
3.0
4.5
5.5
0.1
0.1
0.1
0.1
0.1
0.1
V
I
OUT ≤ 50 µA
*VIN ≥ VT +max
IOL=12 mA
IOL=24 mA
3.0
4.5
5.5
0.36
0.36
0.36
0.44
0.44
0.44
IOL=24 mA
VT +max
VT - min
VH max
VH min
Maximum Positive-
VOUT =0.1 V
3.0
4.5
5.5
2.2
V
V
V
V
Going Input Threshold TA = Worst Case
Voltage
3.2
3.9
Minimum Negative-
VOUT = VCC - 0.1 V
3.0
4.5
5.5
0.5
0.9
1.1
Going Input Threshold TA = Worst Case
Voltage
Maximum Hysteresis
Voltage
VOUT =0.1 V or VCC - 0.1 V
TA = Worst Case
3.0
4.5
5.5
1.2
1.4
1.6
Minimum Hysteresis
Voltage
VOUT =0.1 V or VCC - 0.1 V
TA = Worst Case
3.0
4.5
5.5
0.3
0.4
0.5
IIN
IOLD
IOHD
ICC
Maximum Input
Leakage Current
VIN=VCC or GND
VOLD=1.65 V Max
VOHD=3.85 V Min
VIN=VCC or GND
5.5
5.5
5.5
5.5
0.1
1.0
75
µA
mA
mA
µA
+Minimum Dynamic
Output Current
+Minimum Dynamic
Output Current
-75
40
Maximum Quiescent
Supply Current
(per Package)
4.0
* All outputs loaded; thresholds on input associated with output under test.
+Maximum test duration 2.0 ms, one output loaded at a time.
Notes:1. IIN and ICC @ 3.0 V are guaranteed to be less than or equal to the respective limit @ 5.5 V VCC
2. VH=(VT+)-(VT-)
Rev. 00