Recommended External Component Values  
Below are the recommended component values to ensure the device will operate properly, and that all specified  
parameters will stay within their tolerances. R1 should be greater than 100; recommended value of 220. R1 can be  
up to 500, but in this case the tb2v parameter could be out of it’s specified value (see Electrical Characteristics and  
Note 1). Also, the minimum operating voltage range should be greater than 8.0 V. The following values should be  
adhered to:  
10 kR2 68 kΩ  
1.5 kΩ ≤ R3 47 kΩ  
R4 4.7 kΩ  
R5 4.7 kΩ  
C147 uF  
47 nF C2 470 Nf  
Application Information  
The following is an example of timing calculations using the following external components values:  
R2 = 22 k, R3 = 2.2 k, C2 = 100 nF (Referring to Block Diagram and Typical Application).  
Oscillator Time Base Calculation:  
tb1 duration = tb1 × 4 × R2 × C2 = 1 × 4 × 27e3 × 100e–9 = 10.8 ms  
tb2 duration_g (INT to Gnd) = tb2g × R3 × C2 = 15.5 × 2.2e3× 100e–9 = 3.41 ms  
tb2 duration_v (INT to Vbb) = tb2v × R3 × C2 = 12.1 × 2.2e3× 100e–9 = 2.66 ms  
Intermittent timing calculation:  
T3 = 16 × 4 × tb1 duration = 16 × 4 × 10.8 ms = 691 ms  
T4 = 144 × 4 × tb2 duration_g = 144 × 4 × 3.41 ms = 1.96 s  
(INT connected to Gnd)  
T4 = 144 × 4 × tb2 duration_v = 144 × 4 × 2.66 ms = 1.53 s  
(INT connected to Vbb)  
Wash wipe timing calculation:  
T2 = 96 × 4 × tb1 = 96 × 4 × 10.8 ms = 4.15 s  
T1 Debounce Time Calculation (see T1 Debounce Timing)  
When oscillator is oscillating at tb1:  
T1 minimum = 4 × tb1 = 4 × 10.8 ms = 43.2 ms  
T1 maximum = 2 × 4 × tb1 = 2 × 4 × 10.8 ms = 86.4 ms  
When oscillator is oscillating at tb2:  
T1 minimum (INT connected to Gnd, tb2g) = 4 × tb2 = 4 ×3.41 ms = 13.6 ms  
T1 maximum (INT connected to Gnd, tb2g) = 2 × 4 × tb2 = 2 × 4 × 3.41 ms = 27.3 ms  