IL2904  
*
MAXIMUM RATINGS  
Symbol  
VCC  
Parameter  
Power Supply Voltages  
Value  
Unit  
32  
±16  
V
Single Supply  
Split Supplies  
VIDR  
VICR  
ISC  
Input Differential Voltage Range (1)  
Input Common Mode Voltage Range  
Output Short Circuit Duration  
Junction Temperature  
V
V
±32  
-0.3 to 32  
Continuous  
TJ  
150  
Plastic Packages  
°C  
°C  
Tstg  
Storage Temperature  
-55 to + 125  
Plastic Packages  
IIN  
TL  
Input Current, per pin (2)  
50  
mA  
Lead Temperature, 1mm from Case for 10 Seconds  
260  
°C  
*
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device.  
These are stress ratings only and functional operation of the device at these or any other conditions beyond those  
indicated under “recommended operating conditions” is not implied.  
Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.  
Functional operation should be restricted to the Recommended Operating Conditions.  
+ Derating - Plastic DIP: - 10 mW/°C from 65° to 125°C  
SOI C Package: : - 7 mW/°C from 65° to 125°C  
Notes:  
1. Split Power Supplies.  
2. VIN< -0.3V. This input current will only exist when voltage at any of the input leads is driven negative.  
RECOMMENDED OPERATING CONDITIONS  
Symbol  
VCC  
Parameter  
Min  
M ax  
Unit  
V
DC Supply Voltage  
±2.5  
±15 or  
or 5.0  
30  
TA  
Operating Temperature, All Package Types  
-40  
+ 85  
°C  
This device contains protection circuitry to guard against damage due to high static voltages or electric  
fields. However, precautions must be taken to avoid applications of any voltage higher than maximum rated voltages  
to this high-impedance circuit. For proper operation, VIN and VOUT should be constrained to the range GND(VIN or  
V
OUT)VCC.  
Unused inputs must always be tied to an appropriate logic voltage level (e.g., either GND or VCC). Unused  
outputs must be left open.  
2011, January, Rev. 01