IK8006
3.
Electrical specifications.
3.1. Device variants table programmable by EEPROM.
Table 3.
Device variants table.
Parameter
Versions
Default
Set Point Voltage,
VREG, V
14.0/14.2/14.3/14.4/14.5/14.6/14.7/14.8
14.5
Temperature compensation,
TС, mV/°C
0/-3.5/-5/-7/-10/
720/1100/1200/1400/1500/1800/1920/2250
1400/2000/3100/4000
-7
Cut-in speed,
nstart, rpm
720
3100
Emergency start speed,
nNOT, rpm
Load Response cut-off speed,
nLR, rpm
1500/2100/2500/3000/3100/3500/4000/4500
3100
6
Alternator pole pairs, P
6/7/8
Pre-excitation duty cycle,
TVVE1, %
6/10/14/18/22/26/30/34
14
Load Response start/ramp,
tLRS, s
0/2.5/3/5/6/8/10/12
0/2.5/3/5/6/8/10/12
5
5
Load Response drive/ramp,
tLRD, s
Load Response Control down
ratio, tLRDOWN , s
0.32 to 10 with step 0.32
(Recommended value tLRDOWN= tLRD/4)
0.32
Blind Zone, DFLRCBZ, %
Derivative time, TV, s
3/6/12
6
0
0/0.4/2.5
Frequency at DFM,
fDFM, Hz
60/70/90/100/125/150/250/400/
60
DFM signal polarity
Clamp on DFM, DFMCLAMP
Option “SENSE”
direct/reverse
(5 – 95)/(5 – 100)
Yes/No
direct
(5 – 95)
No
Load response buffer time,
tFILT, s
0.3/2.5
0.3
8
Sep 2018, Rev. 1.10