IK3052A
Absolute Maximum Ratings
Symbol Parameter
Value
20
-0.3 to Vcc
0 to 85
150
Unit
V
Vcc
Vi
DC Supply Voltage
Input Voltage
V
Top
Tj
Operating Free Air Temperature Range
Maximum Junction Temperature
oC
oC
* Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device.
These are stress ratings only and functional operation of the device at these or any other conditions beyond those
indicated under “recommended operating conditions” is not implied.
Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
Operation Conditions
Symbol
Parameter
Value
Unit
Vcc
DC Supply Conditions
2.5 to 18
V
Electrical Characteristics
Tamb = 25°C and Vcc = +5V (unless otherwise specified)
Symbol
Total Current Consumption
Total Supply Current – not taking the
output sinking current into account
Voltage Control Loop
Parameter
Test Condition
Min
Typ
Max
Unit
Tamb
0 < Tamb < 85°C
1.1
1.2
2
Icc
mA
Transconduction Gain (Vctrl). Sink
Tamb
0 < Tamb < 85°C
Tamb
0 < Tamb < 85°C
Tamb
3.5
2.5
Gmv
Vref
Iibv
1
mA/mV
Current Only 1)
1.204
1.186
1.216
1.234
Voltage Control Loop Reference 2)
1.21
V
50
100
Input Bias Current (Vctrl)
nA
0 < Tamb < 85°C
Current Control Loop
Transconduction Gain (Ictrl). Sink
Current Only 3)
Tamb
Gmi
Vsense Current Control Loop Reference 4)
1.5
7
mA/mV
mV
0 < Tamb < 85°C
Iout = 2.5 mA Tamb
0 < Tamb < 85°C
Tamb
196
192
204
208
200
25
50
Iibi
Current out of pin Ictrl at -200mV
μA
0 < Tamb < 85°C
Output Stage
Low output voltage at 10 mA sinking
current
Output Short Circuit Current. Output
to Vcc. Sink Current Only
Tamb
0 < Tamb < 85°C
Tamb
0 < Tamb < 85°C
Vol
Ios
200
mV
mA
27
35
50
1. If the voltage on Vctrl (the negative input of the amplifier) is higher than the positive amplifier input (Vref=1.210V), and
it is increased by 1mV, the sinking current at the output OUT will be increased by 3.5mA.
2. The internal Voltage Reference is set at 1.210V (bandgap reference). The voltage control loop precision takes into
account the cumulative effects of the internal voltage reference deviation as well as the input offset voltage of the trans-
conductance operational amplifier. The internal Voltage Reference is fixed by bandgap, and trimmed to 0.5% accuracy
at room temperature.
3. When the positive input at Ictrl is lower than -200mV, and the voltage is decreased by 1mV, the sinking current at the
output OUT will be increased by 7mA.
4. The internal current sense threshold is set to -200mV. The current control loop precision takes into account the
cumulative effects of the internal voltage reference deviation as well as the input offset voltage of the trans-conduction
operational amplifier.
2011, February, Rev. 01