ICS501  
LOCO™ PLL CLOCK MULTIPLIER  
CLOCK MULTIPLIER  
Crystal Load Capacitors  
External Components  
The total on-chip capacitance is approximately 12 pF. A  
parallel resonant, fundamental mode crystal should be  
used. The device crystal connections should include pads  
for small capacitors from X1 to ground and from X2 to  
ground. These capacitors are used to adjust the stray  
capacitance of the board to match the nominally required  
crystal load capacitance. Because load capacitance can  
only be increased in this trimming process, it is important to  
keep stray capacitance to a minimum by using very short  
PCB traces (and no vias) between the crystal and device.  
Crystal capacitors, if needed, must be connected from each  
of the pins X1 and X2 to ground.  
Decoupling Capacitor  
As with any high-performance mixed-signal IC, the ICS501  
must be isolated from system power supply noise to perform  
optimally.  
A decoupling capacitor of 0.01µF must be connected  
between VDD and the GND. It must be connected close to  
the ICS501 to minimize lead inductance. No external power  
supply filtering is required for the ICS501.  
Series Termination Resistor  
A 33terminating resistor can be used next to the CLK pin  
for trace lengths over one inch.  
The value (in pF) of these crystal caps should equal (CL -12  
pF)*2. In this equation, CL= crystal load capacitance in pF.  
Example: For a crystal with a 16 pF load capacitance, each  
crystal capacitor would be 8 pF [(16-12) x 2 = 8].  
Absolute Maximum Ratings  
Stresses above the ratings listed below can cause permanent damage to the ICS501. These ratings, which are  
standard values for IDT commercially rated parts, are stress ratings only. Functional operation of the device at these  
or any other conditions above those indicated in the operational sections of the specifications is not implied.  
Exposure to absolute maximum rating conditions for extended periods can affect product reliability. Electrical  
parameters are guaranteed only over the recommended operating temperature range.  
Item  
Rating  
Supply Voltage, VDD  
All Inputs and Outputs  
7 V  
-0.5 V to VDD+0.5 V  
-40 to +85° C  
-65 to +150°C  
260°C  
Ambient Operating Temperature  
Storage Temperature  
Soldering Temperature  
Recommended Operation Conditions  
Parameter  
Min.  
Typ.  
Max.  
+70  
Units  
°C  
Ambient Operating Temperature (commercial)  
Ambient Operating Temperature (industrial)  
Power Supply Voltage (measured in respect to GND)  
0
-40  
+3.0  
85  
°C  
+5.25  
V
IDT™ / ICS™ LOCO™ PLL CLOCK MULTIPLIER  
3
ICS501  
REV Q 092209  
 复制成功!