ICS307-03  
SERIALLY PROGRAMMABLE CLOCK SOURCE  
SER PROG CLOCK SYNTHESIZER  
Programming Interface  
The dynamic register within the ICS307-03 controls the entire device and may be reprogrammed any time after  
power is properly applied. If V or R values are changed, the frequency will transition smoothly to the new value  
without glitches or short cycles. However, changing any divider or mux in the output signal path may generate a  
glitch.  
The register is 132 bits in length and accepts the MSB first. The SCLK signal latches the current data bit value in  
the rising edge. It latches the most recently shifted 132 bit values into the control register of device whenever CS is  
high. Care must be taken to ensure that CS is always low until the system is ready to load in a new register value  
and that SCLK is never toggled high when CS is high.  
The register can be programmed any time after power is applied, even while in power-down (pin 15 or bit 112 held  
low) with the waveform and timing shown below:.  
Figure 2: ICS307-03 Programming Timing Diagram  
DIN  
131  
130  
129  
thold  
128  
1
0
2
tsetup  
SCLK  
CS  
tw  
ts  
Table 8: AC Parameters for Programming the ICS307-03  
Parameter  
Condition  
Setup time  
Min.  
2.5  
2.5  
2.5  
10  
Max.  
Units  
ns  
t
SETUP  
t
Hold time after SCLK  
Data wait time  
ns  
HOLD  
t
ns  
W
t
Strobe pulse width  
SCLK Frequency  
ns  
S
200  
MHz  
Programming with VersaClock Software  
The VersaClock II Software not only generates the programming word for the user, it can also be used to program the device  
via the host computer’s parallel port. Demonstration boards are available from IDT that allows the VersaClock II S/W to  
directly connect the ICS307-03 to a Windows based PC’s DB-25 parallel port connector and programmed simply by pressing  
the “Program Part” button.  