ICS251 DATASHEET
AC Electrical Characteristics
Unless stated otherwise,
VDD = 3.3V ±5%,
ambient temperature -40 to +85C
Parameter
Input Frequency
Output Frequency
Output Rise Time
Output Fall Time
Duty Cycle
Symbol
F
IN
Conditions
Fundamental crystal.
Input clock.
20% to 80%, Note 1.
80% to 20%, Note 1.
Note 2.
PLL lock time from
power-up.
PDTS goes high until stable
CLK output, spread
spectrum off.
Min.
5
3
0.314
Typ.
Max. Units
27
150
200
MHz
MHz
MHz
ns
ns
60
10
%
ms
t
OR
t
OF
1
1
40
49–51
4
.6
2
ms
Power-up Time
PDTS goes high until stable
CLK output, spread
spectrum on.
PDTS goes high until
spread spectrum is stable,
spread spectrum on.
4
7
ms
10
50
+200
50
ms
ps
ps
One Sigma Clock Period Jitter
Maximum Absolute Jitter
t
ja
Configuration dependent.
Deviation from Mean.
Configuration dependent.
Note 1: Measured with 15pF load.
Note 2: Duty cycle is configuration dependent. Most configurations are minimum 45% and maximum 55%.
Thermal Characteristics
Parameter
Thermal Resistance Junction to Ambient
Thermal Resistance Junction to Case
Symbol
JA
JA
JA
JC
Conditions
Still air.
1 m/s air flow.
3 m/s air flow.
Min.
Typ.
150
140
120
40
Max. Units
C/W
C/W
C/W
C/W
FIELD PROGRAMMABLE SS VERSACLOCK® SYNTHESIZER
6
OCTOBER 10, 2017