ICS1893AF Data Sheet - Release
Chapter 10 DC and AC Operating Conditions
10.5.20 Auto-Negotiation Fast Link Pulse Timing
Table 10-27 lists the significant time periods for the ICS1893AF Auto-Negotiation Fast Link Pulse. The time
periods consist of timings of signals on the following pins:
• TP_TXP
• TP_TXN
Figure 10-21 shows the timing diagram for one pair of these differential signals, for example TP_TXP minus
TP_TXN.
Table 10-27. Auto-Negotiation Fast Link Pulse Timing
Time
Parameter
Conditions Min.
Typ.
Max.
Units
Period
t1
t2
t3
t4
t5
t6
Clock/Data Pulse Width
–
–
–
–
–
–
–
55
110
–
90
60
125
5
–
70
140
–
ns
µs
Clock Pulse-to-Data Pulse Timing
Clock Pulse-to-Clock Pulse Timing
Fast Link Pulse Burst Width
µs
ms
Fast Link Pulse Burst to Fast Link Pulse Burst
Number of Clock/Data Pulses in a Burst
10
15
15
20
25
30
ms
pulses
Figure 10-21. Auto-Negotiation Fast Link Pulse Timing Diagram
Clock
Pulse
Data
Pulse
Clock
Pulse
Differential
Twisted Pair
Transmit Signal
t1
t1
t3
t2
FLP Burst
FLP Burst
Differential
Twisted Pair
Transmit Signal
t4
t5
ICS1893AF, Rev. D 10/26/04
October, 2004
Copyright © 2004, Integrated Circuit Systems, Inc.
All rights reserved.
133