ICS2304NZ-1
L
OW
S
KEW
PCI/PCI-X B
UFFER
Absolute Maximum Ratings
Stresses above the ratings listed below can cause permanent damage to the ICS2304NZ-1. These ratings,
which are standard values for ICS commercially rated parts, are stress ratings only. Functional operation of
the device at these or any other conditions above those indicated in the operational sections of the
specifications is not implied. Exposure to absolute maximum rating conditions for extended periods can
affect product reliability. Electrical parameters are guaranteed only over the recommended operating
temperature range.
Item
Supply Voltage Range, V
DD
Input Voltage Range, V
I
(see notes 1 and 2)
Output Voltage Range, V
O
(see notes 1 and 2)
Input Clamp Current, I
IK
(V
I
<0 or V
I
>V
DD
)
Output Clamp Current, I
IK
(V
O
<0 or V
O
)
Continuous Total Output Current, I
O
(V
O
= 0 to V
DD
)
Package Thermal Impedance,
θ
JA
(see note 3): PW
Package
Storage Temperature Range, T
stg
Notes:
-0.5 V to 4.3 V
Rating
-0.5 V to V
DD
+ 0.5 V
-0.5 V to V
DD
+ 0.5 V
±50 mA
±50 mA
±50 mA
230.5°C/W
-65°C to 150°C
1. The input and output negative-voltage ratings may be exceeded if the input and output clamp-current
ratings are observed.
2. This value is limited to 4.6 V maximum.
3. The package thermal impedance is calculated in accordance with JESD 51.
Recommended Operation Conditions
Parameter
Supply Voltage, V
DD
High-level Input Voltage, V
IH
Low-level Input Voltage, V
IL
Input Voltage, V
I
High-level Output Current, I
OH
Low-level Output Current, I
OL
Operating Free-air Temperature, T
A
-40
–
0
Min.
3
0.7 x V
DD
Typ.
3.3
Max.
3.6
0.3 x V
DD
V
DD
-24
24
+85
Units
V
V
V
V
mA
mA
°C
Timing Requirements Over Recommended Ranges of Supply Voltage and Operating
Free-air Temperature
Min.
Clock Frequency, f
CLK
0
Typ.
Max.
140
Units
MHz
MDS 2304NZ-1 C
In te grated Circuit Systems
●
3
525 Ra ce Street, San Jose, CA 9512 6
●
Revision 062105
tel (4 08) 297-1 201
●
w w w. i c s t . c o m