 浏览型号ICS1893BYI-10LF的Datasheet PDF文件第73页浏览型号ICS1893BYI-10LF的Datasheet PDF文件第74页浏览型号ICS1893BYI-10LF的Datasheet PDF文件第75页浏览型号ICS1893BYI-10LF的Datasheet PDF文件第76页浏览型号ICS1893BYI-10LF的Datasheet PDF文件第78页浏览型号ICS1893BYI-10LF的Datasheet PDF文件第79页浏览型号ICS1893BYI-10LF的Datasheet PDF文件第80页浏览型号ICS1893BYI-10LF的Datasheet PDF文件第81页  
ICS1893BY-10 - Release  
Chapter 7 Management Register Set  
7.7.2 Acknowledge (bit 5.14)  
The ISO/IEC specification defines bit 5.14 as the Acknowledge bit. When this bit is a:  
Zero, it indicates that the remote link partner has not received the ICS1893BY-10 Link Control Word.  
One, it indicates to the ICS1893BY-10 / STA that the remote link partner has acknowledged reception of  
the ICS1893BY-10 Link Control Word.  
7.7.3 Remote Fault (bit 5.13)  
The ISO/IEC specification defines bit 5.13 as the Remote Fault bit. This bit is set based on the Link Control  
Word received from the remote link partner. When this bit is a logic:  
Zero, it indicates that the remote link partner detects a Link Fault.  
One, it indicates to the ICS1893BY-10 / STA that the remote link partner detects a Link Fault.  
Note: For more information about this bit, see Section 7.3.9, “Remote Fault (bit 1.4)”.  
7.7.4 Technology Ability Field (bits 5.12:5)  
The Technology Ability Field (TAF) bits (bits 5.12:5) determine the specific abilities that the remote link  
partner is advertising. These bits are set based upon the Link Code Word received from the remote link  
partner during the auto-negotiation process. The ISO/IEC specification defines the TAF technologies in  
Annex 28B.  
The ISO/IEC specification reserves bits 5.12:10 for future use. When each of these reserved bits is:  
Read by an STA, the ICS1893BY-10 returns a logic zero.  
Written to by an STA, the STA must use the default value specified in this data sheet.  
ICS uses some reserved bits to invoke auxiliary functions. To ensure proper operation of the  
ICS1893BY-10, an STA must maintain the default value of these bits. Therefore, ICS recommends that an  
STA always write the default value of any reserved bits during all management register write operations.  
7.7.5 Selector Field (bits 5.4:0)  
The Selector Field bits indicate the technology or encoding that the remote link partner is using for the  
Auto-Negotiation message. The ICS1893BY-10 supports only IEEE Std 802.3, represented by a value of  
00001b in bits 5.4:0. The ISO/IEC standard defines the Selector Field technologies in Annex 28A.  
Presently, the IEEE standard defines the following two valid codes:  
00001b (IEEE Std 802.3)  
00010b (IEEE Std 802.9)  
ICS1893BY-10 Rev A 3/24/04  