ICS1893CF Data Sheet - Release  
Chapter 6 Functional Blocks  
When the 10Base-T link is:  
Invalid, and the Smart Squelch function is:  
– Disabled (bit 18.0 is logic one), the Link Monitor Function must detect at least one of the following  
events before transitioning its link from the invalid state to the valid state:  
• More than seven, ISO/IEC-defined, Normal Link Pulses (NLPs)  
• Any valid data  
– Enabled (bit 18.0 is logic zero), the Link Monitor Function must detect at least one of the following  
events before transitioning its link from the invalid state to the valid state:  
• More than seven, ISO/IEC-defined, Normal Link Pulses (NLPs)  
• Any valid data followed by a valid IDL  
Valid, and the Smart Squelch function is:  
– Disabled (bit 18.0 is logic one), the Link Monitor Function continues to report its link as valid as long  
as it continues to detect any of the following:  
• ISO/IEC-defined, Normal Link Pulses (NLPs)  
• Any valid data  
– Enabled (bit 18.0 is logic zero), the Link Monitor Function continues to report its link as valid as long  
as it continues to detect any of the following:  
• ISO/IEC-defined, Normal Link Pulses (NLPs)  
• Any valid data followed by a valid IDL  
Valid, the Link Monitor Function declares the link as invalid if it receives neither data nor NLPs (that is,  
the link shows either no activity or inconsistent activity) for more than 81 to 83 ms. In this case the Link  
Monitor Function sets the Link Status bit to logic zero.  
Note:  
1. An ICS1893CF receives ‘valid data’ when its Twisted-Pair Receiver phase-locked loop can acquire lock  
and extract the receive clock from the incoming data stream for a minimum of three consecutive bit  
times.  
2. When a link is invalid and the Link Monitor Function detects the presence of data, the ICS1893CF does  
not transition the link to the valid state until after the reception of the present packet is complete.  
3. Enabling or disabling the Smart Squelch Function affects the Link Monitor function.  
4. A transition from the invalid state to the valid state does not automatically update the latching-low Link  
Status bit.  
6.5.6 10Base-T Operation: Smart Squelch  
The Smart Squelch Function imposes more stringent requirements on the Link Monitor Function regarding  
the definition of a valid link, thereby providing a level of insurance that spurious noise is not mistaken for a  
valid link during cable installation.  
An STA can control the execution of the ICS1893CF Smart Squelch Function using bit 18.0 (the Smart  
Squelch Inhibit bit in the 10Base-T Operations Register). When bit 18.0 is logic:  
Zero (the default), an ICS1893CF enables its Smart Squelch Function. In this case, the Link Monitor  
must confirm the presence of both data and a valid IDL at the end of the packet before declaring a link  
valid.  
One, an ICS1893CF disables or inhibits its Smart Squelch Function. In this case, the Link Monitor does  
not have to confirm the presence of an IDL to declare a link valid (that is, the reception of any data is  
sufficient).  
In 10Base-T mode, an ICS1893CF appends an IDL to the end of each packet during data transmission.  
The receiving PHY (the remote link partner) sees this IDL and removes it from the data stream.  
ICS1893CF, Rev. F, 03/01/07  
Mar. 2007  
Copyright © 2007, Integrated Device Technology, Inc.  