IC61LV6432
READ CYCLE SWITCHING CHARACTERISTICS
(Over Operating Range)
Symbol
t
KC
t
KH
t
KL
t
KQ
t
KQX
(2)
t
KQLZ
(2,3)
t
KQHZ
(2,3)
t
OEQ
t
OEQX
(2)
t
OELZ
(2,3)
t
OEHZ
(2,3)
t
AS
t
SS
t
WS
t
CES
t
AVS
t
AH
t
SH
t
WH
t
CEH
t
AVH
t
CFG
(4)
Parameter
CycleTime
Clock High Time
ClockLowTime
ClockAccessTime
Clock High to Output Invalid
ClockHightoOutputLow-Z
Clock High to Output High-Z
Output Enable to Output Valid
Output Disable to Output Invalid
OutputEnabletoOutputLow-Z
Output Disable to Output High-Z
AddressSetupTime
AddressStatusSetupTime
Write Setup Time
Chip Enable Setup Time
AddressAdvanceSetupTime
AddressHoldTime
AddressStatusHoldTime
Write Hold Time
Chip Enable Hold Time
AddressAdvanceHoldTime
ConfigurationSetup
-166
Min. Max.
6
2.4
2.4
—
1.5
0
1.5
—
0
0
—
2.5
2.5
2.5
2.5
2.5
0.5
0.5
0.5
0.5
0.5
25
—
—
—
5
—
—
5
5
—
—
3
—
—
—
—
—
—
—
—
—
—
—
-133
Min. Max.
7.5
2.8
2.8
—
1.5
0
1.5
—
0
0
—
2.5
2.5
2.5
2.5
2.5
0.5
0.5
0.5
0.5
0.5
30
—
—
—
5
—
—
5
5
—
—
3
—
—
—
—
—
—
—
—
—
—
—
-117
Min. Max
8.5
3
3
—
1.5
0
1.5
—
0
0
—
2.5
2.5
2.5
2.5
2.5
0.5
0.5
0.5
0.5
0.5
35
—
—
—
5
—
—
6
5
—
—
4
—
—
—
—
—
—
—
—
—
—
—
Unit
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
Notes:
1.
ADVANCE INFORMATION ONLY.
2. Guaranteed but not 100% tested. This parameter is periodically sampled.
3. Tested with load in Figure 2.
4. Configuration signal MODE is static and must not change during normal operation.
Integrated Circuit Solution Inc.
SSR005-0A
02/02/2004
9