X25642
ABSOLUTE MAXIMUM RATINGS*
*COMMENT
Temperature under Bias....................–65°C to +135°C
Storage Temperature ........................–65°C to +150°C
Voltage on any Pin with Respect
Stresses above those listed under “Absolute Maximum
Ratings” may cause permanent damage to the device.
This is a stress rating only and the functional operation
of the device at these or any other conditions above
those indicated in the operational sections of this
specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may
affect device reliability.
to V .........................................................–1V to +7V
SS
D.C. Output Current ............................................. 5mA
(Soldering, 10 seconds) ..............................300°C
RECOMMENDED OPERATING CONDITIONS
Temperature
Commercial
Min.
0°C
Max.
+70°C
Supply Voltage
Limits
5V ±10%
X25642
Industrial
Military
–40°C
–55°C
+85°C
X25642-2.7
2.7V to 5.5V
+125°C
7037 FRM T07
7037 FRM T06
D.C. OPERATING CHARACTERISTICS (Over the recommended operating conditions unless otherwise specified.)
Limits
Symbol
ICC
Parameter
VCC Supply Current (Active)
VCC Supply Current (Standby)
Input Leakage Current
Output Leakage Current
Input LOW Voltage
Units
mA SCK = VCC x 0.1/VCC x 0.9 @ 2MHz,
µA CS = VCC, VIN = V or VCC – 0.3V
Test Conditions
Min.
Max.
5
ISB
1
10
SS
ILI
µA VIN = V to VCC
SS
ILO
10
µA VOUT = V to VCC
SS
(1)
VIL
–1
VCC x 0.3
V
V
(1)
VIH
Input HIGH Voltage
VCC x 0.7 VCC + 0.5
VOL1
VOH1
VOL2
VOH2
Output LOW Voltage
Output HIGH Voltage
Output LOW Voltage
Output HIGH Voltage
0.4
VCC–0.8
V
V
V
V
IOL = 3mA, VCC = 5V
IOH = –1.6mA, VCC = 5V
IOL = 1.5mA, VCC = 3V
IOH = –0.4mA, VCC = 3V
0.4
VCC–0.3
7037 FRM T08
POWER-UPTIMING
Symbol
Parameter
Min.
Max.
Units
ms
(3)
TPUR
Power-up to Read Operation
Power-up to Write Operation
1
1
(3)
TPUW
ms
7037 FRM T09
CAPACITANCE T = +25°C, f = 1MHz, V = 5V
A
CC
Symbol
Parameter
Max.
Units
Test Conditions
(3)
CI/O
Output Capacitance (SO)
8
6
pF
pF
VI/O = 0V
(3)
CIN
Input Capacitance (SCK, SI, CS, WP, HOLD)
VIN = 0V
7037 FRM T10
Notes: (1) V min. and V max. are for reference only and are not tested.
IL
IH
(2) This parameter is periodically sampled and not 100% tested.
(3) t and t are the delays required from the time V is stable until the specified operation can be initiated. These
PUR
PUW
CC
parameters are periodically sampled and not 100% tested.
8