iC-VX
3-CHANNEL DIFFERENTIAL LINE DRIVER
Rev C1, Page 4/11
ELECTRICAL CHARACTERISTICS
Operating Conditions:
VEE= VSUB= 0V, VB= 4.5..30V, VT= VCC= 5V ±10%, Tj= -25..125°C, unless otherwise noted
Item Symbol Parameter
Conditions
Tj
°C
Fig.
Unit
Min.
Typ.
Max.
Total Device
001 VCC-
VEE
Permissible Supply Voltage
Range for Inputs
4.5
11
V
002 VCC
003 VEE
Permis. Supply Voltage VCC
Permis. Supply Voltage VEE
4.5
0
VB
V
V
VB
-4.5V
004 I(VCC)
Supply Current in VCC
0.5
2.4
mA
mA
mA
27
125
1.35
0.89
005 VT
Permis. Bias Supply Voltage VT
Supply Current in VT
4.5
3
VB
12
V
006 I(VT)
PROG at VSUB
PROG open
mA
mA
mA
27
125
6.4
5.1
007 I(VT)
Supply Current in VT
1.3
5
mA
mA
mA
27
125
2.6
2.2
008 VB1,
VB2
Permis. Drivers Supply Voltage
at VB1 and VB2
4.5
0.6
30
V
009 I(VB)
Supply Current in VB
PROG at VSUB,
I(A1..3, NA1..3)= 0
4.8
mA
mA
mA
27
125
2.1
1.5
010 I(VB)
Supply Current in VB
PROG open,
I(A1..3, NA1..3)= 0
0.15
1.2
mA
mA
mA
27
125
0.42
0.31
Driver Outputs A1..3, NA1..3
101 Vs()hi Saturation Voltage hi
PROG to VSUB, VB1 and VB2
connected,
(driver capability 100mA)
Vs(A)hi= VB-V(A,NA);
I(A,NA)= -10mA
I(A,NA)= -30mA
1.0
1.2
2.0
V
V
V
I(A,NA)= -100mA
102 Vs()lo
Saturation Voltage lo
(driver capability 100mA)
PROG to VSUB, VB1 and VB2
connected;
I(A,NA)= 10mA
I(A,NA)= 30mA
I(A,NA)= 100mA
0.9
1.0
1.5
V
V
V
103 Isc()hi
104 Isc()lo
105 SR()
Short-Circuit Current hi
(driver capability 100mA)
PROG to VSUB, VB1 and
VB2 connected, V(A,NA)= 0V
-350
100
100
-100
mA
Short-Circuit Current lo
(driver capability 100mA)
PROG to VSUB, VB1 and
VB2 connected, V(A,NA)= VB
350
mA
Slew-Rate hi lo
(driver capability 100mA)
PROG to VSUB, VB1 and VB2
connected,
V/µs
RL(A,NA)= 750 ,
CL(A,NA)= 100pF