ELECTRICAL CHARACTERISTICS
Operating conditions: +VBAT= 6..16.5V, PGND= GND, COS= 680pF,
RSET= 10k , RKL= 511 , RKLR= 511 , Tj= -40..125 C, unless otherwise noted
Item Symbol Parameter
Conditions
Tj
Fig.
Unit
C
Min.
Typ.
Max.
Autarky Detection
P01 Ri()
Input Resistance at VM, VMR
50
220
k
k
27
27
27
27
100
9
P02 Vvtulo
P03 Vvtuhi
P04 Vhys
P05 Vautlo
P06 Vauthi
P07 Vhys
Lower Undervoltage Threshold at RKL= RKLR= 511 ±1%
KL, KLR
8.75
V
V
Upper Undervoltage Threshold at RKL= RKLR= 511 ±1%
KL, KLR
10.3
1.2
V
V
10
1
Hysteresis Undervoltage
Detection
Vhys= Vvtuhi- Vvtulo
0.8
5.5
V
V
Lower Autarky Threshold at
KL, KLR
RKL= RKLR= 511 ±1%
RKL= RKLR= 511 ±1%
Vhys= Vauthi- Vautlo
V
Upper Autarky Threshold at
KL, KLR
6
V
Hysteresis Autarky Detection
Permissible Voltage at KL, KLR
80
300
48
mV
V
P08 V(VM,
VMR)
P09 tt(VM,
VMR)
Permissible Spurious Pulse Width no undervoltage detection,
at VM, VMR no autarky detection
6.5
µs