iC-HX
preliminar y
Rev A1, Page 6/11
3-CHANNEL DIFFERENTIAL COLD LINE DRIVER
OPERATING CONDITIONS
Operating Conditions: VB1...3 = 4.5...32 V, VCC = 4...5.5 V, Tj = -40...140 °C, unless otherwise noted
input level lo = 0...0.45 V, hi = 2.4 V...VCC, timing diagram see fig. 1
Item
No.
Symbol
Parameter
Conditions
Min.
Propagation Delay Ex
⇒
Ax
Propagation Delay Ex
⇒
Ax
DIFF = lo, Cl() = 100 pF
DIFF = lo, Cl() = 100 pF
DIFF = hi, Cl() = 100 pF
DIFF = hi, Cl() = 100 pF
Ex = hi, DIFF = lo, Cl() = 100 pF,
Rl(Ax, GND) = 5 kΩ
Ex = lo, DIFF = lo, Cl() = 100 pF,
Rl(VB, Ax) = 100 kΩ
Ex = lo, DIFF = lo, Rl(VB, Ax) = 5 kΩ
Ex = hi, DIFF = lo, Rl(Ax, GND) = 5 kΩ
Max.
400
200
100
100
300
200
500
500
250
400
2
0.3
3
ns
ns
ns
ns
ns
ns
ns
ns
ns
ns
µs
µs
Unit
Time Delays
I001 tplh(E-A)
I002 tphl(E-A)
I003
∆tplh(Ax)
Differenz der Propagation Delay
|A1 ⇒
A2|,
|A3 ⇒
A4|,
|A5 ⇒
A6|
I004
∆tphl(Ax)
Differenz der Propagation Delay
|A1 ⇒
A2|,
|A3 ⇒
A4|,
|A5 ⇒
A6|
I005 tplh(ENA) Propagation Delay ENA
⇒
Ax
I006 tplh(ENA) Propagation Delay ENA
⇒
Ax
I007 tphl(ENA) Propagation Delay ENA
⇒
Ax
I008 tphl(ENA) Propagation Delay ENA
⇒
Ax
I009 tphl(DIFF) Propagation Delay DIFF
⇒
A2, A4, A6 E1, E3, E5 = hi, Cl() = 100 pF
I010 tplh(DIFF) Propagation Delay DIFF
⇒
A2, A4, A6 E1, E3, E5 = lo, Cl() = 100 pF
I011 tplh(TNER) Propagation Delay TNER
⇒
NER
I012 tpoff(VBx)
Rl(VB, NER) = 5 kΩ, Cl() = 100 pF
V
2.4V
2.0V
Input/Output
0.8V
0.45V
t
1
0
Figure 1: Reference levels for delays