Discontinued (9/98 - last order; 3/99 last ship)
IBM11T8645HP
8M x 64 144 PIN SO DIMM
Presence Detect (EEPROM) Bus Timing
tF
tR
tHIGH
tLOW
SCL
tSU:STO
tSU:STA
tHD:DAT
tSU:DAT
tHD:STA
SDA IN
tBUF
tDH
tAA
SDA OUT
Presence Detect Operation
Clock and Data Conventions: Data states on the
SDA line can change only during SCL low. SDA
state changes during SCL HIGH are reserved for
indicating start and stop conditions (Figure 1 & Fig-
ure 2).
edge. If an acknowledge is detected and no stop
condition is generated by the master, the slave will
continue to transmit data. If an acknowledge is not
detected, the slave will terminate further data trans-
missions and await the stop condition to return to
standby power mode.
Start Condition: All commands are preceded by the
start condition, which is a HIGH to LOW transition of
SDA when SCL is high. The serial PD device contin-
uously monitors the SDA and SCL lines for the start
condition and will not respond to any command until
this condition has been met.
Figure 1. Data Window
SCL
SDA
Stop Condition: All communications are terminated
by a stop condition, which is a LOW to HIGH transi-
tion of SDA when SCL is HIGH. The stop condition
is also used to place the serial PD device into
standby power mode.
Data Stable
Data
Change
Data Stable
Figure 2. Definition of Start & Stop
Acknowledge: Acknowledge is a software conven-
tion used to indicate successful data transfers. The
transmitting device, either master or slave, will
release the bus after transmitting eight bits. During
the ninth clock cycle the receiver will pull the SDA
line LOW to acknowledge that it received the eight
bits of data (Figure 3).
SCL
SDA
Stop
Bit
Start
Bit
Figure 3. Acknowledge Response From Receiver
The PD device will always respond with an acknowl-
edge after recognition of a start condition and its
slave address. If both the device and a write opera-
tion have been selected, The PD device, will
respond with an acknowledge after the receipt of
each subsequent eight bit word. In the read mode
the PD device will transmit eight bits of data, release
the SDA line and monitor the line for an acknowl-
SCL from
Master
8
9
Data Output
from Trans
Data Output
from Receiver
Acknowledge
©IBM Corporation. All rights reserved.
Use is further subject to the provisions at the end of this document.
75H3164
GA14-4479-02
Rev 11/97
Page 29 of 32