欢迎访问ic37.com |
会员登录 免费注册
发布采购

IBM0612404GT3B-75N 参数 Datasheet PDF下载

IBM0612404GT3B-75N图片预览
型号: IBM0612404GT3B-75N
PDF下载: 下载PDF文件 查看货源
内容描述: [DDR DRAM, 32MX4, 0.75ns, CMOS, PDSO66, 0.400 INCH, PLASTIC, TSOP2-66]
分类和应用: 动态存储器双倍数据速率光电二极管内存集成电路
文件页数/大小: 79 页 / 1017 K
品牌: IBM [ IBM ]
 浏览型号IBM0612404GT3B-75N的Datasheet PDF文件第12页浏览型号IBM0612404GT3B-75N的Datasheet PDF文件第13页浏览型号IBM0612404GT3B-75N的Datasheet PDF文件第14页浏览型号IBM0612404GT3B-75N的Datasheet PDF文件第15页浏览型号IBM0612404GT3B-75N的Datasheet PDF文件第17页浏览型号IBM0612404GT3B-75N的Datasheet PDF文件第18页浏览型号IBM0612404GT3B-75N的Datasheet PDF文件第19页浏览型号IBM0612404GT3B-75N的Datasheet PDF文件第20页  
IBM0612404GT3B  
IBM0612804GT3B  
128Mb Double Data Rate Synchronous DRAM  
Advance Rev 0.2  
Deselect  
The Deselect function prevents new commands from being executed by the DDR SDRAM. The DDR SDRAM  
is effectively deselected. Operations already in progress are not affected.  
No Operation (NOP)  
The No Operation (NOP) command is used to perform a NOP to a DDR SDRAM. This prevents unwanted  
commands from being registered during idle or wait states. Operations already in progress are not affected.  
Mode Register Set  
The mode registers are loaded via inputs A0-A11, BA0 and BA1 while issuing the Mode Register Set Com-  
mand. See mode register descriptions in the Register Definition section. The Mode Register Set command  
can only be issued when all banks are idle and no bursts are in progress. A subsequent executable command  
cannot be issued until t  
is met.  
MRD  
Active  
The Active command is used to open (or activate) a row in a particular bank for a subsequent access. The  
value on the BA0, BA1 inputs selects the bank, and the address provided on inputs A0-A11 selects the row.  
This row remains active (or open) for accesses until a Precharge (or Read or Write with Auto Precharge) is  
issued to that bank. A Precharge (or Read or Write with Auto Precharge) command must be issued and com-  
pleted before opening a different row in the same bank.  
Read  
The Read command is used to initiate a burst read access to an active (open) row. The value on the BA0,  
BA1 inputs selects the bank, and the address provided on inputs A0-Ai, Aj (where [i = 9, j = don’t care] for x8;  
where [i = 9, j = 11] for x4) selects the starting column location. The value on input A10 determines whether or  
not Auto Precharge is used. If Auto Precharge is selected, the row being accessed is precharged at the end  
of the Read burst; if Auto Precharge is not selected, the row remains open for subsequent accesses.  
Write  
The Write command is used to initiate a burst write access to an active (open) row. The value on the BA0,  
BA1 inputs selects the bank, and the address provided on inputs A0-Ai, Aj (where [i = 9, j = don’t care] for x8;  
where [i = 9, j = 11] for x4) selects the starting column location. The value on input A10 determines whether or  
not Auto Precharge is used. If Auto Precharge is selected, the row being accessed is precharged at the end  
of the Write burst; if Auto Precharge is not selected, the row remains open for subsequent accesses. Input  
data appearing on the DQs is written to the memory array subject to the DM input logic level appearing coin-  
cident with the data. If a given DM signal is registered low, the corresponding data is written to memory; if the  
DM signal is registered high, the corresponding data inputs are ignored, and a Write is not executed to that  
byte/column location.  
Precharge  
The Precharge command is used to deactivate (close) the open row in a particular bank or the open row(s) in  
all banks. The bank(s) will be available for a subsequent row access a specified time (t ) after the Pre-  
RP  
charge command is issued. Input A10 determines whether one or all banks are to be precharged, and in the  
case where only one bank is to be precharged, inputs BA0, BA1 select the bank. Otherwise BA0, BA1 are  
treated as “Don’t Care.” Once a bank has been precharged, it is in the idle state and must be activated prior  
to any Read or Write commands being issued to that bank. A precharge command is treated as a NOP if  
there is no open row in that bank, or if the previously open row is already in the process of precharging.  
©IBM Corporation. All rights reserved.  
Use is further subject to the provisions at the end of this document.  
06K0566.F39350  
5/00  
Page 16 of 79  
 复制成功!