GMS81C1102 / GMS81C1202
10.6 Typical Characteristics - GMS81C1102, GMS81C1202
This graphs and tables provided in this section are for de-
sign guidance only and are not tested or guranteed.
The data presented in this section is a statistical summary
of data collected on units from different lots over a period
of time. “Typical” represents the mean of the distribution
while “max” or “min” represents (mean + 3σ) and (mean −
3σ) respectively where σ is standard deviation
In some graphs or tables the data presented are out-
side specified operating range (e.g. outside specified
VDD range). This is for imformation only and divices
are guranteed to operate properly only within the
specified range.
Operating Area
fXIN
Normal Operation
(MHz)
Ta= 25°C
12
IDD−VDD
IDD
Ta=25°C
(mA)
10
8
8
6
4
6
fXIN = 8MHz
4MHz
4
2
2
0
0
VDD
VDD
(V)
(V)
2
3
6
2
3
6
4
5
4
5
Stop Mode
Wake-up Timer Mode
ISTOP−VDD
IWKUP−VDD
IDD
IDD
Ta=25°C
(µA)
(mA)
fXIN=8MHz
0.8
2.0
0.6
0.4
1.5
1.0
°
Ta= - 40 C
fXIN = 8MHz
4MHz
0.2
0
0.5
0
25
4
° °
C, 125 C
VDD
(V)
VDD
(V)
2
3
6
2
3
6
5
4
5
RC-WDT in Stop Mode
IRCWDT−VDD
IDD
(µA)
Ta=25°C
400
fXIN = 4/8 MHz
Frequency affects
the current so little.
300
200
100
0
4MHz
5
VDD
(V)
2
3
6
4
Jan. 2002 ver 2.0
15