Chapter 4. Evaluation Board
Optional setting
The following optional setting in accordance with the application system
specifications is required :
[S1] Optional mask setting
Optional masks available with GMS300 series units can be set by selecting
short posts.
1. Setting of K-input and R-Port for STOP release
Shorting the KSR0 ~ KSR3 and RSR0 ~ RSR3 with the side of H can set the
STOP releasing function by the corresponding KSR0 ~ KSR3 and RSR0 ~
RSR3. If no STOP releasing function is desired, short them with the side of L.
Setting pin
Short post
K0
KSR0
H
K1
KSR1
H
K2
KSR2
H
K3
KSR3
H
R0
RSR0
H
R1
RSR1
H
R2
RSR2
H
R3
RSR3
H
Setting of STOP
No setting of STOP
L
L
L
L
L
L
L
L
2. Setting of pull-up resistor built-in R-Port pull-up resistor can be built in the
R-Port by shorting the corresponding RPU0 ~ RPU3 with the side of H.
If installation of built-in pull-up resistor is not desired, short them with the
side of L.
Setting pin
Short post
R0
RPU0
H
R1
RPU1
H
R2
RPU2
H
R3
RPU3
H
Built-in pull-up resistor installation
No built-in pull-up resistor installation
L
L
L
L