Power Supply option of HTG3400 Series at 5VDC
Continuous Mode:
When powering HTG3400 series modules at 5VDC in continuous mode, an initial 3-minute stabilization time (ts) is
necessary to reach the temperature and the RH outputs with an optimum accuracy.
Pulsed Mode:
When powering HTG3400 series modules in pulsed mode, accurate temperature and RH measurement is reached
instantaneously. Time up (Tup) must be of 5% of the cycle time. Minimum time up (Tup) is 150 ms. Thus minimium
cycle time is 3s.
Supply Voltage (V)
Tup = 5% of
cycle time
Vcc = 5V
Time
Cycle time
Power Supply option of HTG3400 Series at 3.3VDC
At 3.3VDC power supply, there is no measurable impact of type of powering on temperature and RH accuracy.
________________________________________________________________________________________
Humirel HTG3400 Series Datasheet / HPC124 Rev A November 2007