R
ESISTANCE TO PHYSICAL AND CHEMICAL STRESS
- HM1520LF has passed through qualification processes of HUMIREL including vibration, shock, storage, high
temperature and humidity, ESD.
- Additional tests under harsh chemical conditions demonstrate good operation in presence of salt atmosphere,
SO2(O.5%), H2S (0.5%), O3, NOx, NO, CO, CO2, Softener, Soap, Toluene, acids (H2SO4, HNO3, HCl), HMDS,
Insecticide, Cigarette smoke, a non exhaustive list.
- HM152000LF is not light sensitive.
S
PECIFIC PRECAUTIONS
- HM1520LF is protected against reversed polarity.
- If you wish to use HM1520LF in a chemical atmosphere not listed above, consult us.
P
ACKAGE OUTLINE
* Specific length available on request
Dim
Min (mm)
Max (mm)
A
B
C
D
E*
Wire
9.75
4.00
53
10.9
200
Color
10.25
4.50
55
11.4
250
Function
GROUND
SUPPLY
VOLTAGE
OUTPUT
VOLTAGE
W1
W2
W3
White
Blue
Yellow
ORDERING INFORMATION (MULTIPLE PACKAGE QUANTITY OF 10 PARTS)
HM1520LF: HUMIDITY ANALOG VOLTAGE OUTPUT MODULE
ORDERING REFERENCE: HPP805C031
SAMPLE KIT OF HM1520LF
The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsability is assumed for inaccuracies. Furthermore, this information does not
conveyto the purchaser of such devices any license under the patent rights to the manufacturer. Humirel reserves the right to make changes without further notice to any product herein.
Humirelmakes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does Humirel assume any liability arising out of the application
or useof any product or circuit and specifically disclaims any and all liability, including without limitation consequential or incidental damages. « Typical » parameters can and do vary in
differentapplications. All operating parameters, including « Typical » must be validated for each customer applications by customer’s technical experts. Humirel does not convey any license
under itspatent rights nor the rights of others. Humirel products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or
other appli-cation intended to support or sustain life, or for any application in which the failure of the Humirel product could create a situation where personal injury or death may occur.
Should buyerpurchase or use Humirel products for any such unintended or unauthorized application, Buyer shall indemnify and hold Humirel and its officers, employees, subsidaries,
affiliates and distribu-tors harmless against all claims, costs, damages and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of presonal injury or death
associated with such unin-tended or unauthorized use, even if such claim alleges that Humirel was negligent regarding the design or manufacture of the part.Humirel is a registred trade mark
of Humirel.
HPC091 Rev A January 2008