1A Ultra Low Dropout Linear Regulator
TJ4210
ELECTRICAL CHARACTERISTICS (Note 1)
Limits in standard typeface are for TJ=25ºC, and limits in boldface type apply over the full operating temperature range.
(Note 2)
Unless otherwise specified: VIN
= VO(NOM) + 1 V, IL = 10 mA, CIN = 10 uF, COUT = 10 uF, VEN = VIN - 0.3 V
PARAMETER
SYMBOL
VO
TEST CONDITION
VOUT+1 V < VIN < 5.5 V
2.5 V < VIN < 5.5 V
VOUT+1 V < VIN < 5.5 V
10 mA < IL < 1 A
IL = 100 mA
MIN.
TYP.
0
MAX.
UNIT
%
-2
-3
2
3
Output Voltage Tolerance
Adjustable Pin Voltage
(ADJ version)
0.784
0.776
0.816
0.824
VADJ
0.8
0.15
0.60
45
V
-
Line Regulation(Note 3)
ΔVLINE
ΔVLOAD
-
%/V
%
0.40
Load Regulation(Note 3, 4)
-
-
55
65
-
Dropout Voltage(Note 5)
VDROP
mV
500
600
IL = 1 A
-
400
0.40
0.40
0.5
55
0.6
1.0
IL = 100 mA
-
Ground Pin Current(Note 6)
IGND
mA
uA
dB
0.6
1.0
IL = 1 A
-
1
2
Ground Pin Current(Note 7)
IGND_OFF
VEN < 0.2 V
-
f = 1kHz
-
-
Power Supply Rejection Ratio
Thermal Shutdown Temperature
PSRR
f = 1kHz, CFF = 1uF
-
-
65
-
-
TSD
VIL
VIH
IEN
-
-
165
-
ºC
V
Logic Low
Enable threshold
Output = Low
Output = High
VEN = VIN
0.4
-
Logic High
2.0
-
-
V
-
1
Enable Input Current
0.1
uA
Note 1. Stresses listed as the absolute maximum ratings may cause permanent damage to the device. These are for stress ratings. Functional
operating of the device at these or any other conditions beyond those indicated in the operational sections of the specifications is not
implied. Exposure to absolute maximum rating conditions for extended periods may remain possibly to affect device reliability.
Note 2. The minimum operating value for input voltage is equal to either (VOUT,NOM + VDROP) or 2.5V, whichever is greater.
Note 3. Output voltage line regulation is defined as the change in output voltage from the nominal value due to change in the input line voltage.
Output voltage load regulation is defined as the change in output voltage from the nominal value due to change in load current.
Note 4. Regulation is measured at constant junction temperature by using a 10ms current pulse. Devices are tested for load regulation in the
load range from 10mA to 1A.
Note 5. Dropout voltage is defined as the minimum input to output differential voltage at which the output drops 2% below the nominal value.
Dropout voltage specification applies only to output voltages of 2.5V and above. For output voltages below 2.5V, the dropout voltage is
nothing but the input to output differential, since the minimum input voltage is 2.5V
Note 6. Ground current, or quiescent current, is the difference between input and output currents. It's defined by IGND1 = IIN - IOUT under the
given loading condition. The total current drawn from the supply is the sum of the load current plus the ground pin current.
Note 7. Ground current, or standby current, is the input current drawn by a regulator when the output voltage is disabled by an enable signal.
Oct. 2012 – Rev.1.0.6
5/12
HTC