DUAL OPERATIONAL AMPLIFIERS
LM358
ABSOLUTE MAXIMUM RATINGS
CHARACTERISTIC
SYMBOL
VCC
VALUE
±16 or 32
±32
UNIT
V
V
V
Supply Voltage
VI(DIFF)
VI
Differential Input Voltage
Input Voltage
-0.3 to +32
Continuous
Output Short Circuit to GND
VCC≤V TA=25℃ (One Amp)
Operating Temperature Range
Storage Temperature Range
TOPR
TSTG
0~+70
℃
℃
-65 to +150
Electrical characterisitics at specified free-air temperature, V CC=5V(unless otherwise noted)
LM358
PARAMETER
TEST CONDITIONS*
UNIT
MIN
TYP
3
MAX
7
VIO
VCC=5V to MAX,
25℃
VIC=VICRMIN,
VO=1.4V
㎷
Input Offset Voltage
Full Range
9
αVIO
Full Range
7
2
㎶/℃
㎁
Average Temperature Coefficient
of Input Offset Voltage
IIO
25℃
50
VO=1.4V
Full Range
150
Input Offset Current
αllo
Full Range
10
㎀/℃
㎁
Average Temperature Coefficient
of Input Offset Current
IIB
25℃
Full Range
25℃
-20
-250
-500
VO=1.4V
Input Bias Current
0toVCC-1.5
0toVCC-2
VICR
VCC=5V to MAX
V
Common-Mode Input Voltage
Range
Full Range
VCC-1.5
RL≥2㏀
25℃
VOH
VCC=MAX, RL=2㏀
VCC=MAX,
Full Range
26
V
High-Level Output Voltage
Full Range
Full Range
27
28
5
RL≥10㏀
VOL
RL≥10㏀
20
㎷
Low-Level Output Voltage
AVD
VCC=15V,
25℃
Full Range
25℃
25
15
65
100
VO=1V to 11V,
RL≥2㏀
V/㎷
Large-Signal Differential
Voltage Amplification
CMRR
VCC=5V to MAX,
VIC=VICR MIN
80
㏈
㏈
㏈
Common-Mode Rejection Ratio
K
SVR Supply Voltage Rejection
VCC=5V to MAX
25℃
25℃
65
100
Ratio(ΔVCC/ΔVIO)
V01/V02
f=1 kHz to 20kHz
120
-30
Crosstalk Attenuation
VCC=15V,
25℃
Full Range
25℃
-20
-10
10
VID=1V, VO=0
VCC=15V,
㎃
IO
20
30
VID=-1V, VO=15V
VID=-1V,
Full Range
5
Output Current
25℃
12
㎂
㎃
VO=200㎷
IOS
VCC at 5V,
25℃
±40
0.7
1
±60
1.2
2
GND at -5V, VO=0
VO-2.5V, No Load
VCC=MAX,
Short-Circuit Output Current
ICC
Full Range
Full Range
㎃
Supply Current (Two Amplifiers)
VO=0.5VCC, No Load
* All characteristics are measured under open-loop conditions with zero common-mode input voltage unless