AC Switching Specifications
Over recommended temperature (TA = 0°C to 70°C) unless otherwise specified.
Parameter
Symbol
Min. Typ. Max. Units
Test Conditions
Fig. Note
Propagation
Delay Time
to Logic Low
at Output
0.2
0.3
TA = 25°C Pulse: f = 20 kHz,
Duty Cycle = 10%,
6,
8, 9
tPHL
µs
9
10
9
0.2
0.5
IF = 16 mA, VCC = 5.0 V,
RL = 1.9 kΩ, CL = 15 pF,
V
THHL = 1.5 V
0.2
0.1
0.5
0.5
0.7
1.0
TA = 25°C Pulse: f = 10 kHz,
6,
10-14
Duty Cycle = 50%,
IF = 12 mA, VCC = 15.0 V,
RL = 20 kΩ, CL = 100 pF,
THHL = 1.5 V
V
Propagation
Delay Time
to Logic
0.3
0.3
0.5
0.7
TA = 25°C Pulse: f = 20 kHz,
Duty Cycle = 10%,
6,
8, 9
tPLH
µs
IF = 16 mA, VCC = 5.0 V,
RL = 1.9 kΩ, CL = 15 pF,
High at
Output
VTHLH = 1.5 V
0.3
0.2
0.8
0.8
1.1
1.4
TA = 25°C Pulse: f = 10 kHz,
6,
10-14
Duty Cycle = 50%,
10
15
IF = 12 mA, VCC = 15.0 V,
RL = 20 kΩ, CL = 100 pF,
THLH = 2.0 V
V
Propagation
Delay
-0.4
-0.7
0.3
0.3
0.9
1.3
TA = 25°C Pulse: f = 10 kHz,
6,
10-14
t
PLH-tPHL
µs
Duty Cycle = 50%,
Difference
Between
Any 2 Parts
IF = 12 mA, VCC = 15.0 V,
RL = 20 kΩ, CL = 100 pF,
THHL = 1.5 V, VTHLH = 2.0 V
V
Common
VCC = 5.0 V, RL = 1.9 kΩ,
Mode
15
15
30
30
CL = 15 pF, IF = 0 mA
7
7
7, 9
Transient
Immunity at
Logic High
Level Output
|CMH|
|CML|
kV/µs TA = 25°C
VCC = 15.0 V, RL = 20 kΩ,
VCM
=
CL = 100 pF, IF = 0 mA
8, 10
1500 VP-P
Common
Mode
Transient
Immunity at
Logic Low
Level Output
VCC = 5.0 V, RL = 1.9 kΩ,
CL = 15 pF, IF = 16 mA
15
10
30
30
7
7
7, 9
kV/µs TA = 25°C
VCC = 15.0 V, RL = 20 kΩ,
VCM
=
CL = 100 pF, IF = 12 mA
8, 10
1500 VP-P
15
30
VCC = 15.0 V, RL = 20 kΩ,
CL = 100 pF, IF = 16 mA
7
7
8, 10
8, 10
*All typicals at TA = 25°C.
1-42