8
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics  
(HCPL-2611 Option 060 Only)  
Description  
Installation classification per DIN VDE 0110/1.89, Table 1  
for rated mains voltage 300 V rms  
for rated mains voltage 450 V rms  
Climatic Classification  
Pollution Degree (DIN VDE 0110/1.89)  
Maximum Working Insulation Voltage  
Input to Output Test Voltage, Method b*  
Symbol Characteristic Units  
I-IV  
I-III  
55/85/21  
2
V
630  
Vpeak  
Vpeak  
IORM  
VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,  
VPR  
VPR  
1181  
945  
Partial Discharge < 5 pC  
Input to Output Test Voltage, Method a*  
VIORM x 1.5 = VPR, Type and sample test,  
Vpeak  
tm = 60 sec, Partial Discharge < 5 pC  
Highest Allowable Overvoltage*  
(Transient Overvoltage, tini = 10 sec)  
V
6000  
Vpeak  
IOTM  
Safety Limiting Values  
(Maximum values allowed in the event of a failure,  
also see Figure 16, Thermal Derating curve.)  
Case Temperature  
Input Current  
Output Power  
TS  
IS,INPUT  
PS,OUTPUT  
RS  
175  
230  
600  
109  
°C  
mA  
mW  
Insulation Resistance at TS, V = 500 V  
IO  
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN  
60747-5-2, for a detailed description.  
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in  
application.  
IEC/EN/DIN EN 60747-5-2 Insulation Related Characteristics(HCNW137/2601/2611 Only)  
Description  
Installation classification per DIN VDE 0110/1.89, Table 1  
for rated mains voltage 600 V rms  
Symbol Characteristic Units  
I-IV  
I-III  
for rated mains voltage 1000 V rms  
Climatic Classification (DIN IEC 68 part 1)  
Pollution Degree (DIN VDE 0110/1.89)  
Maximum Working Insulation Voltage  
Input to Output Test Voltage, Method b*  
55/100/21  
2
V
1414  
Vpeak  
Vpeak  
IORM  
VIORM x 1.875 = VPR, 100% Production Test with tm = 1 sec,  
VPR  
VPR  
2651  
Partial Discharge < 5 pC  
Input to Output Test Voltage, Method a*  
V
IORM x 1.5 = VPR, Type and sample test,  
2121  
8000  
Vpeak  
tm = 60 sec, Partial Discharge < 5 pC  
Highest Allowable Overvoltage*  
(Transient Overvoltage, tini = 10 sec)  
V
Vpeak  
IOTM  
Safety Limiting Values  
(Maximum values allowed in the event of a failure,  
also see Figure 16, Thermal Derating curve.)  
Case Temperature  
TS  
IS,INPUT  
PS,OUTPUT  
150  
400  
700  
109  
°C  
mA  
mW  
Input Current  
Output Power  
Insulation Resistance at TS, V = 500 V  
RS  
IO  
*Refer to the front of the optocoupler section of the current catalog, under Product Safety Regulations section, IEC/EN/DIN EN  
60747-5-2, for a detailed description.  
Note: Isolation characteristics are guaranteed only within the safety maximum ratings which must be ensured by protective circuits in  