Switching Specifications
Over recommended temperature (TA = 0°C to +70°C), VCC = 5 V, II = 7.5 mA, unless otherwise specified.
Parameter
Symbol
Device
Min. Typ.* Max. Units
Test Conditions
TA = 25°C
Fig. Note
Propagation Delay
Time to High Output
Level
75
ns
tPLH
20
25
48
6, 7, 8
3
100
75
ns
ns
Propagation Delay
Time to Low Output
Level
TA = 25°C
tPHL
50
6, 7, 8
9
4
100
35
ns
ns
RL = 350 Ω
Pulse Width
Distortion
|tPHL-tPLH
|
3.5
CL = 15 pF
13
Propagation Delay
Skew
tPSK
tr
40
ns
ns
ns
ns
12,
13
Output Rise Time
(10-90%)
24
10
30
12
12
Output Fall Time
(90-10%)
tf
Propagation Delay
Time of Enable from
VEH to VEL
tELH
RL = 350 Ω, CL = 15 pF,
VEL = 0 V, VEH = 3 V
10, 11
10, 11
5
6
Propagation Delay
Time of Enable from
VEL to VEH
tEHL
20
ns
RL = 350 Ω, CL = 15 pF,
VEL = 0 V, VEH = 3 V
Common Mode
Transient
Immunity at High
Output Level
HCPL-2602
HCPL-2612
1000 10,000
3500 15,000
VCM = 50 V
VO(MIN) = 2 V,
RL = 350 Ω,
|CMH|
|CML|
V/µs
V/µs
13
13
7, 9,
10
VCM = 300 V II = 0 mA,
TA = 25°C
Common Mode
Transient
Immunity at Low
Output Level
HCPL-2602
HCPL-2612
1000 10,000
3500 15,000
VCM = 50 V
VO(MAX) = 0.8 V,
RL = 350 Ω,
8, 9
10
VCM = 300 V II = 7.5 mA,
TA = 25°C
*All typicals at VCC = 5 V, TA = 25°C.
Package Characteristics
All Typicals at TA = 25°C
Parameter
Sym. Min. Typ. Max. Units
Test Conditions
Fig. Note
Input-Output Momentary
Withstand Voltage*
Input-Output Resistance
Input-Output Capacitance
V
2500
V rms RH ≤ 50%, t = 1 min.,
2, 11
ISO
T = 25°C
A
RI-O
CI-O
1012
0.6
Ω
VI-O = 500 Vdc
f = 1 MHz
2
2
pF
*The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output
continuous voltage rating. For the continuous voltage rating refer to the VDE 0884 Insulation Characteristics Table (if applicable),
your equipment level safety specification or HP Application Note 1074 entitled “Optocoupler Input-Output Endurance Voltage.”
1-321