欢迎访问ic37.com |
会员登录 免费注册
发布采购

HCPL-2731 参数 Datasheet PDF下载

HCPL-2731图片预览
型号: HCPL-2731
PDF下载: 下载PDF文件 查看货源
内容描述: 双通道低输入电流,高增益光电耦合器 [Dual Channel Low Input Current, High Gain Optocouplers]
分类和应用: 光电输出元件
文件页数/大小: 12 页 / 241 K
品牌: HP [ HEWLETT-PACKARD ]
 浏览型号HCPL-2731的Datasheet PDF文件第4页浏览型号HCPL-2731的Datasheet PDF文件第5页浏览型号HCPL-2731的Datasheet PDF文件第6页浏览型号HCPL-2731的Datasheet PDF文件第7页浏览型号HCPL-2731的Datasheet PDF文件第8页浏览型号HCPL-2731的Datasheet PDF文件第9页浏览型号HCPL-2731的Datasheet PDF文件第11页浏览型号HCPL-2731的Datasheet PDF文件第12页  
Package Characteristics  
Device  
Symbol HCPL- Min. Typ.* Max. Units Test Conditions Fig. Note  
Parameter  
Input-Output Momentary  
Withstand Voltage**  
V
2500  
V rms RH 50%,  
t = 1 min.,  
4, 9  
4, 10  
4
ISO  
TA = 25°C  
Option 020  
2730 5000  
2731  
Resistance  
(Input-Output)  
RI-O  
CI-O  
II-I  
1012  
0.6  
pF  
µA  
VI-O = 500 VDC  
RH 45%  
Capacitance  
(Input-Output)  
f = 1 MHz  
11  
5
Input-Input Insulation  
Leakage Current  
0.005  
RH 45%  
V = 500 VDC  
I-I  
Input-Input Insulation  
Leakage Current  
RI-I  
CI-I  
1011  
0.03  
0.25  
5
Capacitance  
(Input-Input)  
2730  
2731  
pF  
5
0730  
0731  
*All Typical values at TA = 25°C unless otherwise noted.  
**The Input-Output Momentary Withstand Voltage is a dielectric voltage rating that should not be interpreted as an input-output  
continuous voltage rating. For the continuous voltage rating refer to the VDE 0884 Insulation Characteristics Table (if appli-  
cable), your equipment level safety specification or HP Application Note 1074 entitled “Optocoupler Input-Output Endurance  
Voltage.”  
Notes:  
common mode pulse, VCM, to assure  
that the output will remain in a Logic  
High state (i.e., VO > 2.0 V). Common  
mode transient immunity in a Logic  
Low level is the maximum tolerable  
(negative) dVCM/dt of the common  
mode pulse, VCM, to assure that the  
output will remain in a Logic Low state  
(i.e., VO < 0.8 V).  
9. In accordance with UL 1577, each  
optocoupler is proof tested by  
applying an insulation test voltage  
> 3000 V rms for 1 second (leakage  
detection current limit, II-O < 5 µA).  
10. In accordance with UL 1577, each  
optocoupler is proof tested by  
applying an insulation test voltage  
> 6000 V rms for 1 second (leakage  
detection current limit, II-O < 5 µA).  
11. Measured between the LED anode and  
cathode shorted together and pins 5  
through 8 shorted together.  
12. Derate linearly above 65°C free-air  
temperature at a rate of 2.3 mW/°C for  
the SO-8 package.  
1. Pin 5 should be the most negative  
voltage at the detector side.  
2. Each channel.  
3. DC CURRENT TRANSFER RATIO  
(CTR) is defined as the ratio of output  
collector current, IO, to the forward  
LED input current, IF, times 100%.  
4. Device considered a two-terminal  
device: pins 1, 2, 3, and 4 shorted  
together, and pins 5, 6, 7, and 8  
shorted together.  
5. Measured between pins 1 and 2  
shorted together, and pins 3 and 4  
shorted together.  
6. Common mode transient immunity in a  
Logic High level is the maximum  
tolerable (positive) dVCM/dt of the  
7. In applications where dV/dt may  
exceed 50,000 V/µs (such as static  
discharge) a series resistor, RCC  
,
should be included to protect the  
detector IC from destructively high  
surge currents. The recommended  
value is RCC = 110 .  
8. Use of a 0.1 µF bypass capacitor  
connected between pins 5 and 8  
adjacent to the device is  
recommended.  
1-117