3.3. Interrupts  
The RFM23 is capable of generating an interrupt signal when certain events occur. The module notifies the  
microcontroller that an interrupt event has been detected by setting the nIRQ output pin LOW = 0. This interrupt  
signal will be generated when any one (or more) of the interrupt events (corresponding to the Interrupt Status bits)  
shown below occur. The nIRQ pin will remain low until the microcontroller reads the Interrupt Status Register(s)  
(Registers 03h04h) containing the active Interrupt Status bit; the nIRQ output signal will then be reset until the  
next change in status is detected. All of the interrupts must be enabled by the corresponding enable bit in the  
Interrupt Enable Registers (Registers 05h06h). All enabled interrupt bits will be cleared when the microcontroller  
reads the interrupt status register. If the interrupt is not enabled when the event occurs inside of the module it will not  
trigger the nIRQ pin, but the status may still be read correctly at anytime in the Interrupt Status registers.  
POR  
Def.  
Function/De  
scription  
D7  
D6  
D5  
D4  
D3  
D2  
D1  
D0  
Add R/W  
R
Interrupt Status 1  
Interrupt Status 2  
ifferr  
iswdet  
enfferr  
itxffafull  
ipreaval  
itxffaem  
ipreainval  
irxffafull  
irssi  
iext  
iwut  
ipksent  
ilbd  
ipkvalid  
ichiprdy  
icrcerror  
ipor  
03  
R
04  
enrxffafull  
enpkvalid  
encrcerr  
or  
entxffafull entxffaem  
enext enpksent  
R/W  
Interrupt Enable1  
00h  
01h  
05  
R/W  
Interrupt Enable 2 enswdet  
enpreaval enpreainval  
enrssi  
enwut  
enlbd  
enchiprdy  
enpor  
06  
See ―Register 03h. Interrupt/Status 1,‖ and ―Register 04h. Interrupt/Status 2,‖ for a complete list of interrupts.  
3.4. Device Code  
The device version code is readable from "Register 01h. Version Code (VC)". This is a read only register.  
D7  
D6  
D5  
D4  
D3  
D2  
D1  
D0  
POR Def.  
Notes  
Add R/W Function/Description  
01  
R
Device Version  
0
0
0
vc[4]  
vc[3] vc[2] vc[1] vc[0]  
00h  
DV  
19  
Tel: +86-755-82973805  
Fax: +86-755-82973550  
E-mail: sales@hoperf.com  
http://www.hoperf.com  