RFM22  
8.5. Low Battery Detector  
A low battery detector (LBD) with digital read-out is integrated into the module. A digital threshold may be  
programmed into the lbdt[4:0] field in "Register 1Ah. Low Battery Detector Threshold". When the digitized battery  
voltage reaches this threshold an interrupt will be generated on the nIRQ pin to the microcontroller. The  
microcontroller will then need to verify the interrupt by reading "Register 03h. Interrupt/Status 1" and ―Register 04h.  
Interrupt/Status 2,‖. If the LBD is enabled while the module is in SLEEP mode, it will automatically enable the RC  
oscillator which will periodically turn on the LBD circuit to measure the battery voltage. The battery voltage may also  
be read out through "Register 1Bh. Battery Voltage Level" at any time when the LBD is enabled. The Low Battery  
Detect function is enabled by setting enlbd=1 in "Register 07h. Operating Mode and Function Control 1".  
POR  
Def.  
Function/Descri  
ption  
D7  
D6  
D5  
D4  
D3  
D2  
D1  
D0  
Ad  
1A  
1B  
R/W  
R/W  
R
Low Battery  
Detector Threshold  
Battery Voltage  
Level  
14h  
lbdt[4]  
lbdt[3]  
lbdt[2]  
lbdt[1]  
lbdt[0]  
0
0
0
vbat[4] vbat[3]  
vbat[2] vbat[1] vbat[0]  
The LBD output is digitized by a 5-bit ADC. When the LBD function is enabled, enlbd = 1 in "Register 07h.  
Operating Mode and Function Control 1", the battery voltage may be read at anytime by reading "Register 1Bh.  
Battery Voltage Level". A Battery Voltage Threshold may be programmed to register 1Ah. When the battery voltage  
level drops below the battery voltage threshold an interrupt will be generated on nIRQ pin to the microcontroller if  
the LBD interrupt is enabled in ―Register 06h. Interrupt Enable 2,‖ . The microcontroller will then need to verify the  
interrupt by reading the interrupt status register, Addresses 03 and 04H. The LSB step size for the LBD ADC is 50  
mV, with the ADC range demonstrated in the table below. If the LBD is enabled the LBD and ADC will automatically  
be enabled every 1 s for approximately 250 μs to measure the voltage which minimizes the current consumption in  
Sensor mode. Before an interrupt is activated four consecutive readings are required.  
BatteryVoltage =1.7+50mV × ADCValue  
ADC Value  
VDD Voltage [V]  
< 1.7  
0
1
1.71.75  
2
……  
29  
1.751.8  
……  
3.13.15  
3.153.2  
>3.2  
30  
31  
57  