欢迎访问ic37.com |
会员登录 免费注册
发布采购

RFM22-868-S1 参数 Datasheet PDF下载

RFM22-868-S1图片预览
型号: RFM22-868-S1
PDF下载: 下载PDF文件 查看货源
内容描述: ISM收发器模块 [ISM Transceiver module]
分类和应用: ISM频段
文件页数/大小: 150 页 / 3773 K
品牌: HOPERF [ HOPERF ]
 浏览型号RFM22-868-S1的Datasheet PDF文件第142页浏览型号RFM22-868-S1的Datasheet PDF文件第143页浏览型号RFM22-868-S1的Datasheet PDF文件第144页浏览型号RFM22-868-S1的Datasheet PDF文件第145页浏览型号RFM22-868-S1的Datasheet PDF文件第146页浏览型号RFM22-868-S1的Datasheet PDF文件第147页浏览型号RFM22-868-S1的Datasheet PDF文件第148页浏览型号RFM22-868-S1的Datasheet PDF文件第150页  
RFM22  
13. Description: Phase Noise at 100 kHz and 1 MHz offsets can occasionally jump to be out of spec by 5 dB.  
Impacts: The 5 dB shift may impact adjacent channel selectivity and TX spectral mask.  
Workaround: The issue has a bi-modal nature and can toggle between two states of phase noise.  
Resolution: Will be fixed in the next revision.  
14. Description: Some non-standard frequencies are not supported.  
Impacts: Operation in frequencies between 240280 MHz and 480560 MHz should be avoided.  
Workaround: These are non-standard bands and should result in no customer impact; no workaround at this  
time.  
Resolution: Will be fixed in the next revision.  
15. Description: RSSI is not correct using default settings.  
Impacts: No impact.  
Workaround: Set the following registers: Reg 6Ah lnacomp[3:0] = 0010 and pgathres[1:0] = 11.  
Resolution: Will be fixed in the next revision.  
16. Description: The reference design listed in the data sheet does not meet the specified harmonic suppression as  
listed in the data sheet.  
Impacts: May not meet harmonic specification with listed reference design.  
olution: Change Low Pass Filter Reference Design.  
17. Description: LBD voltage read-back can occasionally be incorrect. If the LBD battery voltage register is read  
during the same cycle that the register is being updated, it will read the previously read value and not the updated  
value. The LBD measurement cycle is 250  s and the update period is 30  s.  
Impacts: May need to use majority polling or use the LBD interrupt instead.  
Workaround: Read the register two or three consecutive times to ensure it is correct or use the LBD interrupt.  
Resolution: Will be fixed in the future revision.  
18. Description: For TX data rates higher than 100 kbps a register change is required. The cpcurr[1:0] bits in Reg  
58h should be changed to 11 (default = 01).  
Impacts: May slightly degrade phase noise in the 100 to 300 kHz region.  
Workaround: Change Reg 58h to 11.  
Resolution: None planned.  
Workaround: If random selection of the TX antenna is not desired, then a single antenna may be manually  
selected by using the antdiv register in 08h.  
Resolution: Will be fixed in the next revision.  
19. Description: Use the PA Reference Design in data sheet revision 0.4  
Impacts: Not using the reference design on data sheet 0.4 may create a maximum voltage swing higher than  
expected on the PA output.  
Workaround: See data sheet.  
Resolution: Informational only.  
149  
Tel: +86-755-82973805  
Fax: +86-755-82973550  
E-mail: sales@hoperf.com  
http://www.hoperf.com  
 复制成功!