RF31
The total settling time (cold start) of the PLL after the calibration can be calculated as TCS = TS + TO.
Register 53h. PLL Tune Time
Bit
D7
D6
D5
D4
D3
D2
D1
pllt0
R/w
D0
pllts[4:0]
R/w
Name
Type
Reset value = 01010010
Bit
Name
Function
PLL Soft Settling Time (TS).
This register will set the settling time for the PLL from a previous locked
frequency in Tune mode. The value is configurable between 0 μs and 310 μs,
in 10 μs intervals. The default plltime corresponds to 100 μs. See formula
above.
7:3
pllts[4:0]
PLL Settling Time (TO).
This register will set the time allowed for PLL settling after the calibrations are
completed. The value is configurable between 0 μs and 70 μs, in 10 μs steps.
The default pllt0 corresponds to 20 μs. See formula above.
pllt0
2:0
Register 54h. PA Boost
Bit
D7
D6
D5
D4
inv_pre_th
R/w
D3
D2
D1
ldo_pa_boost
R/w
D0
pa_vbias_boost
R/w
Reserved[7:6]
R/w
Name
Type
Reset value = 01010100
Bit
7:6
5:2
1
Name
Function
Reserved[7:6]
inv_pre_th[5:2]
ldo_pa_boost
pa_vbias_boost
Reserved.
Invalid Preamble Threshold.
LDO PA Boost.
0
PA VBIAS Boost.
Invalid preamble will be evaluated during this period: (invalid_preamble_Threshold x 4) x Bit Rate period.
113