Operating temperature rang
Operating temperature rang is the rang of ambient temperatures in which the filter
can be operated continuously. -10℃ ~ +60℃
Storage temperature rang
Storage temperature rang is the rang of ambient temperatures at which the filter can
be stored without damage.
Conditions are as specified elsewhere in these specifications. -40℃ ~ +70℃
Reference temperature
+25℃
2.1 Maximum Rating
DC voltage
AC voltage
VDC
Vpp
12
10
V
V
Between any terminals
Between any terminals
2.2 Electrical Characteristics
Source impedance
Z
S
=50Ω
Load impedance
Z
L
=2kΩ//3pF
Freq
Min
Insertion attenuation
36.50MHz
12.5
Reference level
38.00MHz
4.6
34.42MHz
-0.4
Relative attenuation
33.50MHz
18.3
32.00MHz
42.0
39.50MHz
42.0
25.00~32.00MHz
37.0
Sidelobe
39.50~45.00MHz
35.0
Reflected wave signal suppression
1.2 us … 6.0 us after main pulse
40.0
(test pulse 250 ns ,
carrier frequency 36.50 MHz)
Feedthrough signal suppression
1.2 us … 6.0 us after main pulse
45.0
(test pulse 250 ns ,
carrier frequency 36.50 MHz)
Temperature coefficient
T
A
=25℃
typ
14.5
6.1
1.1
20.3
50.0
50.0
42.0
40.0
50.0
max
16.5
7.6
2.6
22.3
-
-
-
-
-
dB
dB
dB
dB
dB
dB
dB
dB
dB
52.0
-72
-
dB
ppm/k
2