Operating temperature rang
Operating temperature rang is the rang of ambient temperatures in which the filter
can be operated continuously. -10℃ ~ +60℃
Storage temperature rang
Storage temperature rang is the rang of ambient temperatures at which the filter can
be stored without damage.
Conditions are as specified elsewhere in these specifications. -40℃ ~ +70℃
Reference temperature
+25℃
2.1 Maximum Rating
DC voltage
AC voltage
VDC
Vpp
12
10
V
V
Between any terminals
Between any terminals
2.2 Electrical Characteristics
Source impedance
Zs=50Ω
Load impedance
Z
L
=2kΩ//3pF
Freq
T
A
=25℃
typ
43.81
14.8
6.0
7.0
0.3
0.2
2.7
2.7
52.0
50.0
47.0
41.0
40.0
45.0
max
43.91
16.6
-
-
-
1.4
4.2
4.2
-
-
MHz
dB
MHz
MHz
dB
dB
dB
dB
dB
dB
dB
dB
dB
dB
Center frequency
Insertion attenuation
Reference level
Fo
43.81MHz
min
43.71
13.0
-
-
-
-1.0
1.2
1.2
36.0
35.0
38.0
35.0
34.0
38.0
B
3dB
B
30dB
41.28MHz
46.34MHz
40.81MHz
Relative attenuation
46.81MHz
39.81MHz
47.81MHz
35.06~39.06MHz
39.06~39.81MHz
Sidelobe
47.81~50.06MHz
50.06~55.06MHz
Pass bandwidth
Reflected wave signal suppression
1.3 us … 6.0 us after main pulse
(test pulse 250 ns ,
carrier frequency 43.81 MHz)
Feedthrough signal suppression
1.3 us … 1.2 us before main pulse
(test pulse 250 ns ,
carrier frequency 43.81 MHz)
Group delay ripple
(p-p)
40.81 ~ 46.81 Mhz
42.0
52.0
dB
45.0
54.0
dB
-
50
-
ns