Basic Switches
SX Series
Subminiature
ORDER GUIDE by as cending electrical capability
PIN PLUNGER
Electrical
Data and O.F. max. R.F. min. P.T. max. O.T. min. D.T. max. O.P.*
Catalog
Lis ting
UL Code newtons newtons
mm
inches
mm
inches
mm
inches
mm
inches
Recommended for
Logic level loads
5VDC, 2mA; SPNO
Page 20
ounces
ounces
11SX91-T
12SX2-T
3SX1-T
At
Left
1,39
5
0,28
1
0,51
.020
0,1
.004
0,1
.004
8,13
.320
Best reliability
(Bifurcated gold contacts)
.010 Amp 0,7 to 1.39
0,28
0,51
.020
0,1
.004
0,051
.002
8,13
.320
H
2.5 to 5
1
Applications requiring gold
contacts (1SX type)
1 Amp
1,39
0,28
0,51
.020
0,1
.004
0,13
.005
8,13
.320
D
5
1
12SX1-T
Best reliability with
1 Amp
1,39
0,28
0,51
0,1
0,076
8,13
higher current rating
(Bifurcated gold contacts)
D
5
1
.020
.004
.003
.320
12SX3-T
Lowest differential travel
1 Amp
1,39
0,28
0,51
0,1
0,025
8,13
with bifurcated gold contacts
H
5
1
.020
.004
.001
.320
13SX21-T
Applications requiring gold
contacts. 11SX type.
1 Amp
D
1,39
5
0,28
1
0,51
.020
0,1
.004
0,051
.002
8,13
.320
23SX39-T
(MS24547-2)
MIL-S-8805 applications
requiring gold contacts
+180°F (82°C) max. use
1 Amp
D
1,39
5
0,28
1
0,51
.020
0,1
.004
0,13
.005
8,13
.320
23SX39-T2
(MS24547-5)
As above, with
T2 terminals
1 Amp
D
1,39
5
0,28
1
0,51
.020
0,1
.004
0,13
.005
8,13
.320
93SX39-T
.156⍯ wide, with gold
1 Amp
1,39
0,28
0,51
0,1
0,13
8,13
M8805/109-03
contacts +180°F (82°C)
D
5
1
.020
.004
.005
.320
411SX21-T
M8805/106-01
+400°F (204°C)
for 100 hours
1,39
5
0,28
1
0,51
.020
0,1
.004
0,13
.005
8,13
.220
G
L
413SX21-T
M8805/106-02
+400°F (204°C)
for 100 hours
1,39
5
0,28
1
0,51
.020
0,1
.004
0,051
.002
8,13
.220
Dim. Dwg. Fig. 1
(Except Fig. 2
for 91SX39-T
11SX1-T
11SX21-T
11SX22-T
17SX21-T
1SX1-T
Lowest differential travel
Most applications
3 Amps
0,97
3.5
0,21
0.75
0,51
.020
0,1
.004
0,025
.001
8,13
.320
E
and 93SX34-T)
5 Amps 0,7 to 1,39
0,28
1
0,51
.020
0,1
.004
0,051
.002
8,13
.320
A
2.5 to 5
For use in sealed
enclosures.
5 Amps
1,39
5
0,28
1
0,51
.020
0,1
.004
0,076
.003
8,13
.320
A
Best stability under varying
humidity. 11SX type.
5 Amps
1,39
5
0,28
1
0,51
.020
0,1
.004
0,051
.002
8,13
.320
A
Up to 7 amps load handling
Low differential travel
Added overtravel
7 Amps
1,39
5
0,28
1
0,51
.020
0,1
.004
0,13
.005
8,13
.320
B
1SX12-T
1SX48-T
2SX1-T
7 Amps
1,39
5
0,28
1
0,51
.020
0,1
.004
0,051
.002
8,13
.320
C
7 Amps
1,39
5
0,28
1
0,51
.020
0,25
.010
0,13
.005
8,13
.320
B
Lower force
7 Amps
0,83
0,28
0,51
0,1
0,13
8,13
B
3
1
.020
.004
.005
.320
4SX1-T
Operating in temperature
to +400°F (204°C)
for 100 hours
7 Amps
1,39
5
0,28
1
0,51
.020
0,1
.004
0,13
.005
8,13
.320
I
21SX1-T
Best stability under varying
humidity (1SX type)
7 Amps
1,39
5
0,28
1
0,51
.020
0,1
.004
0,13
.005
8,13
.320
B
21SX39-T
MIL-S-8805 application
7 Amps
1,39
0,28
0,51
0,1
0,13
8,13
(MS24547-1)
requirements +180°F (82°C)
F
5
1
.020
.004
.005
.320
21SX39-T2
MIL-S-8805 application
7 Amps
1,39
0,28
0,51
0,1
0,13
8,13
(MS24547-4)
requirements +180°F (82°C)
F
5
1
.020
.004
.005
.320
91SX39-T
M8805/109-01
.156⍯ wide version
of standard SX +180°F
(82°C)
7 Amps
1,39
5
0,28
1
0,51
.020
0,1
.004
0,13
.005
8,13
.320
F
*±0,38 mm
±.015 in.
22 Honeywell Sensing and Control
For application help: call1-800-537-6945.