POTENTIAL APPLICATIONS
Medical:
Industrial:
-
-
-
-
-
-
-
-
-
-
-
Airflow monitors
-
-
-
-
-
-
-
Barometry
Anesthesia machines
Blood analysis machines
Gas chromatography
Gas flow instrumentation
Kidney dialysis machines
Oxygen concentrators
Pneumatic controls
Respiratory machines
Sleep apnea equipment
Ventilators
Flow calibrators
Gas chromatography
Gas flow instrumentation
HVAC
Life sciences
Pneumatic controls
Table 1. Absolute Maximum Ratings1
Parameter
Min.
-0.3
Max.
6.0
Unit
Vdc
V
Supply voltage (Vsupply)
Voltage on any pin
-0.3
Vsupply + 0.3
•
ESD susceptibility (human body model)
Storage temperature
3
kV
-40 [-40]
85 [185]
°C [°F]
Soldering time and temperature:
Lead solder (SIP, DIP)
Peak reflow (SMT)
4 s max. at 250 °C [482 °F]
15 s max. at 250 °C [482 °F]
Table 2. Operating Specifications
Parameter
Min.
Typ.
Max.
Unit
Supply voltage (Vsupply)2:
3.3 Vdc
3.0
4.75
3.33
5.03
3.6
5.25
Vdc
5.0 Vdc
Sensors are either 3.3 Vdc or 5.0 Vdc based on listing selected.
Supply current:
3.3 Vdc supply
5.0 Vdc supply
•
-
1.6
2
•
•
•
1
•
•
•
•
2.1
3
85 [185]
85 [185]
mA
Compensated temperature range4
Operating temperature range5
Startup time (power up to data ready)
Response time
-20 [-4]
-40 [-40]
°C [°F]
°C [°F]
ms
•
•
•
2.5
•
5
•
97.5
•
±0.25
±2
ms
Upper output clipping limit
Lower output clipping limit
Accuracy6
%Vsupply
%Vsupply
%FSS BFSL
%FSS8
%FSS8
Total error band7
•
Output resolution
0.03
•
•
2
www.honeywell.com/sensing