LINEAR MAGNETIC FIELD SENSORS  
HMC1001/1002 SPECIFICATIONS  
Characteristics  
Conditions*  
Min  
Typ  
5
Max  
12  
Unit  
Volts  
ohm  
°C  
Bridge Supply  
Vbridge referenced to GND  
Bridge current = 10mA  
Bridge Resistance  
Operating Temperature (4)  
Storage Temperature (4)  
Field Range (4)  
600  
-55  
-55  
-2  
850  
1200  
150  
175  
+2  
Unbiased  
°C  
Full scale (FS), total applied field  
gauss  
%FS  
Linearity Error (4)  
Best fit straight line ±1 gauss  
±2 gauss  
0.1  
1
0.5  
2
Hysteresis Error (4)  
3 sweeps across ±2 gauss  
3 sweeps across ±2 gauss  
0.05  
0.05  
0.10  
0.10  
%FS  
%FS  
Repeatability Error (4)  
S/R Repeatability (1)  
S/R Repeatability (2)  
10  
100  
Output variation after alternate S/R pulses  
2
µV  
Bridge Offset  
Offset = (OUT+) (OUT-), Field=0 gauss  
-60  
2.5  
-15  
30  
mV  
after Set pulse, Vbridge=8V  
Sensitivity  
S/R Current = 3A  
3.2  
29  
4.0  
mV/V/gauss  
nV/ Hz  
µgauss  
MHz  
Noise Density (4)  
Resolution (4)  
Bandwidth (4)  
OFFSET Strap  
Noise at 1 Hz, Vbridge=5V  
Bandwidth=10Hz, Vbridge=5V  
Magnetic signal (lower limit = DC)  
Measured from OFFSET+ to OFFSET-  
27  
5
2.5  
0.39  
51  
3.5  
ohm  
OFFSET Strap Tempco (4) TA = -40 to 125° C  
%/° C  
OFFSET Field (4)  
Set/Reset Strap  
Field applied in sensitive direction  
Measured from S/R+ to S/R-  
46  
56  
1.8  
5
mA/gauss  
ohm  
1.5  
3.2  
0.37  
Set/Reset Current (2) (3) (4) 2 µs current pulse, 1% duty cycle  
3.0  
Amp  
Set/Reset Tempco (4)  
T A = -40 to 125° C  
%/° C  
Disturbing Field (4)  
Sensitivity starts to degrade.  
Use S/R pulse to restore sensitivity.  
3
gauss  
Sensitivity Tempco (4)  
T A = -40 to 125° C Vbridge=8V  
-0.32  
-0.3  
-0.28  
%/° C  
%/° C  
Ibridge=5mA  
-0.06  
Bridge Offset Tempco (4)  
T A = -40 to 125° C no Set/Reset  
±0.03  
±0.001  
Vbridge=5V  
with Set/Reset  
Resistance Tempco (4)  
Cross-Axis Effect (4)  
T A = -40 to 125° C  
0.25  
%/° C  
Cross field=1gauss no Set/Reset  
(see AN-205) with Set/Reset  
±3  
+0.5  
%FS  
Max. Exposed Field (4)  
Weight  
No perming effect on zero reading  
10000  
gram  
gauss  
HMC1001  
HMC1002  
0.14  
0.53  
(1) VBridge = 4.3V, IS/R = 3.2A, VOUT = VSET VRESET  
(2) If VBridge = 8.0V, IS/R = 2.0A, lower S/R current leads to greater output variation.  
(3) Effective current from power supply is less than 1mA.  
(4) Not tested in production, guaranteed by characterization.  
(*) Tested at 25° C except otherwise stated.  
Units: 1 gauss (g) = 1 Oersted (in air), = 79.58 A/m, 1G = 10E-4 Tesla, 1G = 10E5 gamma.  