THERMOSTATS - COMMERCIAL  
2450CM/2455RM Series Ceramic and  
Phenolic Manual Reset Thermostats  
2450RC/2450RCH/2455RC Series  
Ceramic Automatic Reset Thermostats  
A temperature-sensitive bimetal disc, electrically isolated from the switch,  
actuates the normally closed contacts. The contacts open when the  
surface or ambient temperatures increase to the operating snap point of  
the calibrated disc. The circuit will stay open above room ambient  
temperature until the manual reset button is pressed. Response to  
temperature changes is extremely rapid due to the inherently low mass  
of the disc and the small size of the product.  
A temperature-sensitive bimetal disc, electrically isolated from the switch,  
actuates the normally closed contacts. The contacts open when the  
surface or ambient temperatures increase to the operating snap point of  
the calibrated disc. Response to temperature changes is extremely rapid  
due to the inherently low mass of the disc and the small size of the  
product.  
Reset type:  
Amperage capacity:  
Housing material:  
Operating temperature range:  
Environmental exposure range:  
Automatic  
15 A resistive max.  
Reset type:  
Amperage capacity:  
Housing material:  
Operating temperature range: 52 °C to 232 °C [125 °F to 450 °F] (ceramic)  
52 °C to 150 °C [125 °F to 302 °F] (phenolic)  
Manual  
15 A resistive max.  
Ceramic or phenolic  
Ceramic  
0 °C to 260 °C [32 °F to 500 °F]  
–20 °C to 287 °C [0 °F to 550 °F]  
Environmental exposure range: 10 °C to 260 °C [50 °F to 500 °F] (ceramic)  
10 °C to 177 °C [50 °F to 350 °F] (phenolic)  
2450RC  
16,00  
[0.379]  
2450CM  
1,04 [0.041] MAX TRAVEL OF  
RESET BUTTON  
ON CONTACT OPENING  
15,98  
[0.629]  
9,63  
14,48  
[0.379]  
12,90 [0.570]  
[0.508]  
14,43 DIA.  
[0.568]  
9,55  
[0.376]  
9,04  
[0.356]  
0,51  
[0.020]  
16,0 DIA.  
[0.630]  
0,51  
[0.020]  
SERIES NAME  
2450RC Ceramic Automatic Reset Thermostat  
SERIES NAME  
2450CM Ceramic Manual Reset Thermostat  
2450RCH  
2,36 [0.093] DIA.  
1,57 [0.062] DEEP  
2455RM  
1,04 [0.041] MAX TRAVEL  
OF RESET BUTTON ON  
CONTACT OPENING  
14,48  
2,77 DIA. RESET  
[0.109] BUTTON  
[0.570]  
12,90  
[0.508]  
14,43 DIA.  
[0.568]  
9,04  
[0.356]  
15,88 ON CONTACT  
[0.625] CLOSING  
16,0 DIA.  
[0.630]  
ENCLOSED DISK  
14,43 DIA.  
[0.568]  
11,91  
[0.469]  
SERIES NAME  
2450RCH Ceramic Automatic Reset Thermostat  
16,0 DIA.  
[0.630]  
0,51  
[0.020]  
2455RC  
SERIES NAME  
2455RM Phenolic Manual Reset Thermostat  
14,43 DIA.  
[0.568]  
11,91  
[0.469]  
16,0 DIA.  
[0.630]  
0,51  
[0.020]  
SERIES NAME  
2455RC Ceramic Automatic Reset Thermostat  
28  