Tꢄermostats ꢃine Guide
Well over 5,000 reasons to
cꢄoose honeywell.
Commercial
Tꢄermostats
With over 5,000 quality
components in our thermostat
line, we meet any domestic
or international need for
commercial or precision snap-
action solutions.
2450A Series
2450Cꢁ Series
2450CꢁG Series
Use
heat detection
automatic
high current
manual
low voltage
manual
Reset type
phenolic, epoxy seal cap
and terminals
Commercial tꢄermostats:
You’ll find Honeywell quality
in a wide array of small
Housing material
ceramic
ceramic
Functional property
Amperage
open or close on rise
3 A
open on rise
15 A/10 A
open on rise
0.5 A
and major appliances,
47 °C to 107 °C
[117 °F to 225 °F]
52 °C to 232 °C
[125 °F to 450 °F]
52 °C to 232 °C
[125 °F to 450 °F]
automotive applications, office
copy machines and HVAC
equipment, plus heat and
smoke detectors. Whether
it’s military or aerospace
industries, or your office
building, each Honeywell S&C
thermostat can be designed
to offer the performance and
reliability you demand, and the
service you need.
Operating temperature range
Environmental exposure range
0 °C to 150 °C
[32 °F to 302 °F]
10 °C to 260 °C
[50 °F to 500 °F]
10 °C to 260 °C
[50 °F to 500 °F]
WE-1 gold alloy cross
point
WE-1 gold alloy cross
point
Contacts
silver/nickel alloy
UL, CSA, VDE
Approvals
UL
UL, CSA, VDE
Precision tꢄermostats:
A highly reliable lineup
for potential high-end
Commercial
Tꢄermostats
applications, including
2450hR Series
2450hRG Series
2450R Series
computers, copy machines,
aircraft, radar, medical
Use
high current
automatic
low current
automatic
phenolic
open on rise
0.5 A
high current
automatic
equipment and electronic
control systems — each
designed to meet the most
stringent environmental
conditions for dielectric
strength, moisture, resistance,
vibration, shock and hermetic
seal. And S&C offers custom-
packaged thermostats for
complete application flexibility.
Reset type
Housing material
Functional property
Amperage
phenolic
phenolic
open or close on rise
15 A/10 A
open or close on rise
15 A/10 A
0 °C to 150 °C
[32 °F to 302 °F]
0 °C to 150 °C
[32 °F to 302 °F]
0 °C to 150 °C
[32 °F to 302 °F]
Operating temperature range
Environmental exposure range
-18 °C to 177 °C
[0 °F to 350 °F]
-18 °C to 177 °C
[0 °F to 350 °F]
-18 °C to 177 °C
[0 °F to 350 °F]
WE-1 gold alloy cross
point
Contacts
silver/nickel alloy
UL, CSA
silver/nickel alloy
UL, CSA
Approvals
UL, CSA
2ꢀ
www.honeywell.com/sensing