Commercial
Tꢄermostats
2450RC Series
2450RCG Series
2450RG Series
Use
high current
low voltage
low voltage
Reset type
automatic
automatic
automatic
Housing material
Functional property
Amperage
ceramic
ceramic
phenolic
open or close on rise
15 A/10 A
open or close on rise
0.5 A
open or close on rise
0.5 A
Operating temperature range
0 °C to 260 °C [32 °F to 500 °F]
0 °C to 260 °C [32 °F to 500 °F]
-20 °C to 287 °C [0 °F to 550 °F]
WE-1 gold alloy cross point
UL, CSA, VDE
0 °C to 150 °C [32 °F to 302 °F]
-18 °C to 177 °C [0 °F to 350 °F]
WE-1 gold alloy cross point
UL, CSA
Environmental exposure range -20 °C to 287 °C [0 °F to 550 °F]
Contacts
silver/nickel alloy
UL, CSA, VDE
Approvals
Commercial
Tꢄermostats
2455R Series
2455RA Series
2455RVB Series
Use
high current
heat detection
high current
Reset type
automatic
automatic
automatic
Housing material
Functional property
Amperage
phenolic
phenolic, epoxy seal cap and terminals
close on rise
ceramic, epoxy overmold
open or close on rise
15 A/10 A
open or close on rise
15 A/10 A
3 A
Operating temperature range
0 °C to 150 °C [32 °F to 302 °F]
47 °C to 107 °C [117 °F to 225 °F]
0 °C to 150 °C [32 °F to 302 °F]
WE-1 gold alloy cross point
UL
-12 °C to 105 °C [10 °F to 250 °F]
-18 °C to 121 °C [0 °F to 250 °F]
silver/nickel alloy
Environmental exposure range -18 °C to 177 °C [0 °F to 350 °F]
Contacts
silver/nickel alloy
UL, CSA, VDE
Approvals
UL, CSA, VDE
www.honeywell.com/sensingꢀ
3ꢀ