Manual Switches
NT Series
Sealed Toggle Switches
PULL-TO-UNLOCK OPTION
When ordering pull-to-unlock toggle list- der a INTI-1 pull-to-unlock toggle switch
ings, add the suffix letter shown in the with the lever locked in the center posi-
chart below to the standard toggle listing tion, add the letter E; i.e., INTI-1E.
and the MS number. For example, to or-
LOCKING CONFIGURATIONS
A
B
D
E
F
G
H
Locked In
Center and
Extreme Position
(Keyway Side)
Locked Out Of
Center And
Extreme Position
(Keyway Side)
Locked Out
Of Center
Position
Locked In
Extreme Position
(Opposite Keyway)
Locked In
Extreme Position
(Keyway Side)
Locked In
Three Positions
Locked In
Center Position
J
K
L
M
N
P
Locked Out Of
Center And
Extreme Position
(Opposite Keyway)
Locked In
Center And
Extreme Position
(Opposite Keyway)
Locked Out Of
Locked Out Of
And Into
Extreme Position
(Keyway Side)
Locked Out Of
Extreme Position
(Keyway Side)
And Into
Extreme Position
(Opposite Keyway)
Locked Out Of
Extreme Position
(Opposite Keyway)
MOUNTING DIMENSIONS:
(For reference only)
0,0 = mm
0.00 = inches
Key:
Panel cutout
With locking ring
Without locking ring
Note:
0 1,4/.06 MIN DEEP TO ACCOMMODATE LOCKING
RING. 15PA87 PANEL SEAL REQUIRES BLIND HOLE
TO INSURE SEAL INTEGRITY
DIM ‘‘A’’
1-pole
2 & 4-pole
29,5/1.16
34,4/1.35
NOTES:
Terminal Circuit Identification
1. Pull-to-unlock levers have 10,7/42 dia. knob
2. Locking ring, lockwasher, 2 hexnuts and terminal screws are
furnished unassembled.
Solder Terminals
Bushing mounting
torque is 10–15
in./lbs.
Terminal screw
mounting torque is 5
in./lbs. max.
Quick Connect Terminals
110
Honeywellɀ MICRO SWITCH Sensing and Controlɀ1-800-537-6945 USAɀ ⍣1-815-235-6847 Internationalɀ1-800-737-3360 Canada