HI-3110  
TRANSMIT ERROR COUNTER REGISTER: TEC  
TEC7:0  
(Write, SPI Op-code 0x26)  
(Read, SPI Op-code 0xEC)  
7
6
5
4
3
2
1
0
LSB  
MSB  
TheTEC register reflects the current value of the CANTransmit Error Counter. This register can be written by SPI command for test  
purposes.  
Bit Name  
R/W Default Description  
R/W 0x00 Transmit Error Counter bits <7:0>.  
7-0 TEC7:0  
0 £TEC £ 95: Error active status.  
96£TEC £ 127: Error active status. Error warning flag, ERRW, set in STATF register. This  
may be used to generate a hardware interrupt if ERRWIE bit is set in STATFE register.  
128 £TEC£ 255: Error passive status. Transmit error passive flag, TXERRP, set in ERR  
register. ERRPalso set in STATF register. This may be used to generate a hardware interrupt if  
ERRPIE bit is set in STATFE register.  
TEC > 255: Bus-off status. Bus-off flags, BUSOFF, set in ERR and STATF registers. The  
latter may be used to generate a hardware interrupt if BUSOFFIE bit is set in STATFE register.  
The HI-3110 will, after entering bus-off state, automatically recover to error active status  
without host intervention if the BOR bit is set in control register CTRL0 and 128 x 11  
consecutive recessive bits are detected on the bus. If the BOR bit is not set, bus-off recovery is  
managed by the host.  
RECEIVE ERROR COUNTER REGISTER: REC  
REC7:0  
(Write, SPI Op-code 0x24)  
(Read, SPI Op-code 0xEA)  
7
6
5
4
3
2
1
0
LSB  
MSB  
The REC register reflects the current value of the CAN Receive Error Counter. This register can be written by SPI command for test  
purposes.  
Bit Name  
R/W Default Description  
R/W 0x00 Receiver Error Counter bits <7:0>.  
7-0 TEC7:0  
0 £ REC £ 95: Error active status.  
96 £ REC £ 127: Error active status. Error warning flag, ERRW, set in STATF register. This  
may be used to generate a hardware interrupt if ERRWIE bit is set in STATFE register.  
128 £ REC £ 255: Error passive status. Receive error passive flag, RXERRP, set in ERR  
register. ERRPalso set in STATF register. This may be used to generate a hardware interrupt if  
ERRPIE bit is set in STATFE register.  