 浏览型号HT46C47(18DIP)的Datasheet PDF文件第5页浏览型号HT46C47(18DIP)的Datasheet PDF文件第6页浏览型号HT46C47(18DIP)的Datasheet PDF文件第7页浏览型号HT46C47(18DIP)的Datasheet PDF文件第8页浏览型号HT46C47(18DIP)的Datasheet PDF文件第10页浏览型号HT46C47(18DIP)的Datasheet PDF文件第11页浏览型号HT46C47(18DIP)的Datasheet PDF文件第12页浏览型号HT46C47(18DIP)的Datasheet PDF文件第13页  
HT46R46/C46/R47/C47/R48/R49  
Program Counter  
met, the next instruction, which has already been  
fetched during the present instruction execution, is dis-  
carded and a dummy cycle takes its place while the cor-  
rect instruction is obtained.  
During program execution, the Program Counter is used  
to keep track of the address of the next instruction to be  
executed. It is automatically incremented by one each  
time an instruction is executed except for instructions,  
such as ²JMP² or ²CALL² that demand a jump to a  
non-consecutive Program Memory address. For the  
Cost-Effective A/D Type series of microcontrollers, note  
that the Program Counter width varies with the Program  
Memory capacity depending upon which device is se-  
lected. However, it must be noted that only the lower 8  
bits, known as the Program Counter Low Register, are  
directly addressable by user.  
The lower byte of the Program Counter, known as the  
Program Counter Low register or PCL, is available for  
program control and is a readable and writable register.  
By transferring data directly into this register, a short  
program jump can be executed directly, however, as  
only this low byte is available for manipulation, the  
jumps are limited to the present page of memory, that is  
256 locations. When such program jumps are executed  
it should also be noted that a dummy cycle will be in-  
serted.  
When executing instructions requiring jumps to  
non-consecutive addresses such as a jump instruction,  
a subroutine call, interrupt or reset, etc., the  
microcontroller manages program control by loading the  
required address into the Program Counter. For condi-  
tional skip instructions, once the condition has been  
The lower byte of the Program Counter is fully accessi-  
ble under program control. Manipulating the PCL might  
cause program branching, so an extra cycle is needed  
to pre-fetch. Further information on the PCL register can  
be found in the Special Function Register section.  
Program Counter Bits  
Mode  
b11  
0
b10  
0
b9  
0
b8  
0
b7  
0
b6  
0
b5  
0
b4  
0
b3  
0
b2  
0
b1  
0
b0  
0
Initial Reset  
External Interrupt  
0
0
0
0
0
0
0
0
0
1
0
0
Timer/Event Counter  
Overflow  
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
1
1
0
1
0
0
0
0
A/D Converter Interrupt  
Skip  
Program Counter + 2  
Loading PCL  
PC11 PC10 PC9 PC8 @7  
@6  
#6  
@5  
#5  
@4  
#4  
@3  
#3  
@2  
#2  
@1  
#1  
@0  
#0  
Jump, Call Branch  
Return from Subroutine  
#11  
#10  
#9  
S9  
#8  
S8  
#7  
S7  
S11 S10  
S6  
S5  
S4  
S3  
S2  
S1  
S0  
Program Counter  
Note: PC11~PC8: Current Program Counter bits  
@7~@0: PCL bits  
#11~#0: Instruction code address bits  
S11~S0: Stack register bits  
For the HT46R49, the Program Counter is 12 bits wide, i.e. from b11~b0.  
For the HT46R47 and HT46R48, the Program Counter is 11 bits wide, i.e. From  
b10~b0, therefore the b11 column in the table is not applicable.  
For the HT46R46, the Program Counter is 10 bits wide, i.e. from b9~b0, therefore the b11 and  
b10 the columns in the table are not applicable.  
Rev. 1.00  
9
April 18, 2007