BS83B08-3/B12-3/B16-3/B16G-3/C24-3  
8-Bit Touch Key Flash MCU  
RAM Data Memory  
The Data Memory is a volatile area of 8-bit wide RAM internal memory and is the location where  
temporary information is stored.  
Structure  
Divided into two sections, the first of these is an area of RAM, known as the Special Function Data  
Memory. Here are located registers which are necessary for correct operation of the device. Many of  
these registers can be read from and written to directly under program control, however, some remain  
protected from user manipulation.  
Device  
Capacity  
160´8  
Bank 0  
60H~FFH  
60H~FFH  
Bank 1  
¾
Bank 2  
¾
Bank 3  
¾
BS83B08-3  
BS83B12-3  
80H~FFH  
288´8  
¾
¾
BS83B16-3  
60H~FFH  
80H~FFH  
80H~FFH  
80H~FFH  
288´8  
512´8  
¾
¾
BS83B16G-3  
BS83C24-3  
80H~FFH  
80H~FFH  
General Purpose Data Memory  
The second area of Data Memory is known as the General Purpose Data Memory, which is reserved  
for general purpose use. All locations within this area are read and write accessible under program  
control.  
The overall Data Memory is subdivided into several banks for the devices. The Special Purpose Data  
Memory registers are accessible in all banks, with the exception of the EEC register at address 40H,  
which is only accessible in Bank 1. Switching between the different Data Memory banks is achieved  
by setting the Bank Pointer to the correct value. The start address of the Data Memory for all devices is  
the address 00H.  
Special Function Register Description  
Most of the Special Function Register details will be described in the relevant functional section,  
however several registers require a separate description in this section.  
Indirect Addressing Registers - IAR0, IAR1  
The Indirect Addressing Registers, IAR0 and IAR1, although having their locations in normal RAM  
register space, do not actually physically exist as normal registers. The method of indirect addressing  
for RAM data manipulation uses these Indirect Addressing Registers and Memory Pointers, in  
contrast to direct memory addressing, where the actual memory address is specified. Actions on the  
IAR0 and IAR1 registers will result in no actual read or write operation to these registers but rather to  
the memory location specified by their corresponding Memory Pointers, MP0 or MP1. Acting as a  
pair, IAR0 and MP0 can together access data from Bank 0 while the IAR1 and MP1 register pair can  
access data from any bank. As the Indirect Addressing Registers are not physically implemented,  
reading the Indirect Addressing Registers indirectly will return a result of ²00H² and writing to the  
registers indirectly will result in no operation.  