HMC697LP4 / 697LP4E
v01.0309
SiGe WIDEBAND DIRECT QUADRATURE
MODULATOR, 200 - 4000 MHz
Electrical Specifications, (continued)
Parameter
Conditions
Min.
200
Typ.
15
Max.
4000
Units
RF Output
RF Frequency Range
RF Return Loss
MHz
dB
LO Input
LO Frequency Range
LO Input Power
200
-6
4000
+6
MHz
dBm
dB
0
LO Port Return Loss
Baseband Input Port
Baseband Input DC Voltage (Vbbdc)
Baseband Input DC Bias Current (Ibbdc)
12
+1.4
+4.5
+1.5
90
+1.6
+5.5
V
10
Single-ended.
μA
pF
Single-ended Baseband Input Capacitance
DC Power Requirements
De-embed to the lead of the device.
See Test Conditions Below
4.5
Supply Voltage (Vcc1, Vcc2)
+5.0
168
V
Supply Current (Icc1 + Icc2)
mA
Test Conditions: Unless Otherwise Specified, the Following Test Conditions Were Used
Parameter
Condition
+25 °C
200 kHz
+1.5V
Temperature
Baseband Input Frequency
Baseband Input DC Voltage (Vbbdc)
Baseband Input AC Voltage
(Peak to Peak Differential, I and Q)
1.6V
Baseband Input AC Voltage for OIP3 Measurement (Peak to Peak Differential, I and Q)
800 mV per tone @ 150 & 250 kHz
Frequency Offset for Output Noise Measurements
Supply (Vcc1, Vcc2)
20 MHz
+5.0V
LO Input Power
0 dBm
LO Input Mode
Single-Ended through LOP
Mounting Configuration
Refer to HMC697LP4E Application Schematic Herein
Uncalibrated
Sideband & Carrier Feedthrough
Calibrated vs. Uncalibrated Test Results
During the Uncalibrated Sideband and Carrier Suppression tests, care is taken to ensure that the I/Q signal paths from
the Vector Signal Generator (VSG) to the Device Under Test (DUT) are equal. The “Uncalibrated, +25 °C” Sideband
and Carrier Suppression plots were measured at room temperature, while the “Uncalibrated, over Temperature”
Sideband and Carrier Suppression plots represent the worst case uncalibrated suppression levels measured at T=
-40 °C, +25 °C, and +85 °C.
The “Calibrated, + 25 °C” Sideband Suppression data was plotted after a manual adjustment of the I/Q amplitude
balance and I/Q phase offset (skew) at +25 °C, and at each LO input power level. The +25 °C adjustment settings
were held constant during tests over temperature. The “Calibrated, over Temperature” plots represent the worst case
calibrated Sideband Suppression levels at T= -40 °C, +25 °C, and +85 °C.
The “Calibrated, +25 °C” Carrier Suppression data was plotted after a manual adjustment of the Ip/In & Qp/Qn DC
offsets at +25 °C, and at each LO input power level. The +25 °C adjustment settings were held constant during tests
over temperature. The “Calibrated, over Temperature” plots represent the worst case Carrier Suppression levels
measured at T= -40 °C, +25 °C, and +85 °C.