CDP6402, CDP6402C
Static Electrical Specifications
at T
A
= -40
o
C to +85
o
C, V
DD
±10%,
Except as noted
CONDITIONS
CDP6402
V
O
(V)
V
IH
0.5, 4.5
0.5, 9.5
Input Leakage
Current
I
IN
Any
Input
V
IN
(V)
-
-
0,5
0,10
Three-State Output
Leakage Current
I
OUT
0, 5
0, 10
Operating Current
(Note 2)
I
DD1
-
-
Input Capacitance
Output Capacitance
NOTES:
1. Typical values are for T
A
= 25
o
C and nominal V
DD
2. I
OL
= I
OH
= 1µA.
3. Operating current is measured at 200kHz or V
DD
= 5V and 400kHz for V
DD
= 10V, with open outputs (worst-case frequencies for
CDP1802A system operating at maximum speed of 3.2MHz).
C
IN
C
OUT
-
-
0, 5
0,10
0, 5
0,10
-
-
V
DD
(V)
5
10
5
10
5
10
5
10
-
-
(NOTE 1)
TYP
-
-
±10
-4
±10
-4
±10
-4
±10
-4
1.5
10
5
10
(Continued)
LIMITS
CDP6402C
(NOTE 1)
TYP
-
-
-
-
±10
-4
-
1.5
-
5
10
PARAMETER
Input High Voltage
MIN
V
DD
-2
7
-
-
-
-
-
-
-
-
MAX
-
-
±1
±2
±1
±10
−
−
7.5
15
MIN
V
DD
-2
-
-
-
-
-
-
-
-
-
MAX
-
-
±1
-
±1
-
-
-
7.5
15
UNITS
V
V
µA
µA
µA
µA
mA
mA
pF
pF
5-77